PMML0251A rev.2 - 02/2013
Refrigerant piping & refrigerant charge
31
ENGLISH
13.4.2 System Installation (examples)
Height Difference Between Indoor Units and Distributor
It is recommended to install all indoor units at the same height.
When the height difference between the indoor units due to build-
ing construction is necessary, this should be less than the value
indicated in the table. Install the branch pipe at the same height of
indoor units or lower, but never higher.
Indoor unit
Indoor
unit
Height Difference between two
indoors smaller than H
Smaller than 3
m
Branch pipe
≤
≤
O.U. (HP)
H (m)
Premium
3
3
4-10
10
Standard
3-10
3
Installing Distributor
1
Install the Distributor supplied by HITACHI on request.
A tee can not be installed instead of a branch pipe.
2
Installing the distributor
Fix the branch pipe horizontally to the pillar, wall or ceiling. Pip-
ing must not be fixed rigidly to the wall as thermal expansion and
contraction can cause pipe fracture.
Horizontal
To Indoor
Unit
To Outdoor unit
Vertical
To Indoor unit
Fixing the branch pipe to
the surface of pillar or wall
Horizontal
Horizontal
Fixing the branch pipe to
ceiling or beam
(pictures as example)
N O T E
Fix the piping from outside of insulation or inserting absorber be-
tween the pipe and a fixing metal.
3
Correct position of distributor (available also for quad instal-
lation)
• This is the correct position:
G r e a t e r
than 0.5 m
Main pipe
Refrigerant direction
Up
Branch pipe
Main pipe
Refrigerant di-
rection
Down
• This is wrong position.
Main pipe
Refrigerant direction
Branch pipe
Branch pipe
Refrigerant di-
rection
Branch pipe
Main pipe
(pictures as example)
_PMML0251A_r2.indb 31
06/02/2013 9:05:07
Содержание RAS-10HNCE
Страница 2: ..._PMML0251A_r2 indb 2 06 02 2013 9 04 41 ...
Страница 46: ...PMML0251A rev 2 02 2013 46 Safety summary control device setting _PMML0251A_r2 indb 46 06 02 2013 9 05 17 ...
Страница 118: ...118 Sicherheitsübersicht steuerungseinstellungen PMML0251A rev 2 02 2013 _PMML0251A_r2 indb 118 06 02 2013 9 06 09 ...
Страница 154: ...154 Dépannage PMML0251A rev 2 02 2013 _PMML0251A_r2 indb 154 06 02 2013 9 06 33 ...
Страница 226: ...226 PMML0251A rev 2 02 2013 _PMML0251A_r2 indb 226 06 02 2013 9 07 28 ...
Страница 298: ...298 Problemen oplossen PMML0251A rev 2 02 2013 _PMML0251A_r2 indb 298 06 02 2013 9 08 18 ...
Страница 370: ...370 Αντιμετωπιση προβληματων PMML0251A rev 2 02 2013 _PMML0251A_r2 indb 370 06 02 2013 9 09 06 ...
Страница 371: ..._PMML0251A_r2 indb 371 06 02 2013 9 09 06 ...
Страница 372: ...PMML0251A rev 2 02 2013 Printed in Spain _PMML0251A_r2 indb 372 06 02 2013 9 09 07 ...