![Hitachi RAC-50DH7 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/hitachi/rac-50dh7/rac-50dh7_service-manual_139700063.webp)
– 73 –
8. Overload control circuit (OVL control circuit)
Judgement value according to the rotation speed
(internal judgement value)
External judgement value
Detection
resistor
Translation
(R503)
DC current
Rotation speed data
To power module
negative
terminal
Primary
CT
0V
0V
Voltage amp.
circuit
Judgement OVL
with respect to
externally set
value
Judgement OVL
according to the rotation
speed
A/D
converter
OVL start current data
Selects data according
to the rotation speed and
DC voltage.
RC filter circuit
(Internal judgement)
DC voltage
DC
current
Rotation speed
Motor control
process
A/D
converter
A/D
converter
AX-6V01 micro computer
Fig. 8-1 Overload Control System Configuration
Fig. 8-2
●
Overload control is to decrease the speed of the compressor and reduce the load when the load on the
air conditioner increases to an overload state, in order to protect the compressor, electronic components
and power breaker.
●
Overloads are judged by comparing the DC current level and set value.
●
Fig. 8-1 shows the overload control system configuration and Fig. 8-2 is a characteristic diagram of
overload judgement values. There are two judgement methods-external judgement which compares the
externally set value with the DC current value regardless of the rotation speed and internal judgement
which compares the set value that varies according to the rotation speed programmed in the microcomputer
software with the DC current value.
Содержание RAC-50DH7
Страница 30: ... 29 CIRCUIT DIAGRAM Wired Remote Control ...
Страница 31: ... 31 CIRCUIT DIAGRAM MODEL RAD 50DH7A RAD 60DH7A RAD 70DH7A ...
Страница 32: ... 33 CIRCUIT DIAGRAM MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 35: ... 39 51 53 53 55 57 49 29 66 Heating ...
Страница 76: ... 86 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 79: ... 89 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 82: ... 92 CHECKING THE REMOTE CONTROLLER ...
Страница 87: ... 97 16 ...
Страница 101: ...HITACHI PM NO 0411E Printed in Malaysia RAD 50DH7A RAC 50DH7 RAD 60DH7A RAC 60DH7 RAD 70DH7A RAC 70DH7 ...