![Hitachi RAC-50DH7 Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/hitachi/rac-50dh7/rac-50dh7_service-manual_139700052.webp)
– 62 –
(3) Smoothing capacitor (C501, C502, C503)
This smoothes (averages) the voltage rectified by the diode stacks.
(4) Smoothing capacitor (C020)
This smoothes (averages) the voltage rectified by the diode
stack2. A DC voltage is generated in the same way as in
Fig. 1-3.
Voltage b side of C020 is about 330V.
(5) C001 to C003, C012 to C015, C007, C008, NF COIL1, COIL,
C22 ~ C25 absorb electrical noise generated during operation
of compressor, and also absorb external noise entering from
power line to protect electronic parts.
(6) Surge absorber, Varistor 1, 2, 3,
absorbs external power surge.
(7) Inrush protective resistor (R002, R003)
This works to protect from overcurrent when power is turned
on.
< Reference >
●
When inrush protective resistor is
defective, diode stack may
malfunction. As a result, DC voltage
is not generated and no operation can
be done.
●
Be careful to avoid an electric shock as a
high voltage is generated. Also take care
not to cause a short-circuit through incorrect
connection of test equipment terminals. The
circuit board could be damaged.
Fig. 1-3
Fig. 1-2
a
b
OV
OV
OV
Vd
DC voltage
(approx. 260-360V during operation)
Smoothing Capacitors
SPM2
Содержание RAC-50DH7
Страница 30: ... 29 CIRCUIT DIAGRAM Wired Remote Control ...
Страница 31: ... 31 CIRCUIT DIAGRAM MODEL RAD 50DH7A RAD 60DH7A RAD 70DH7A ...
Страница 32: ... 33 CIRCUIT DIAGRAM MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 35: ... 39 51 53 53 55 57 49 29 66 Heating ...
Страница 76: ... 86 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 79: ... 89 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 82: ... 92 CHECKING THE REMOTE CONTROLLER ...
Страница 87: ... 97 16 ...
Страница 101: ...HITACHI PM NO 0411E Printed in Malaysia RAD 50DH7A RAC 50DH7 RAD 60DH7A RAC 60DH7 RAD 70DH7A RAC 70DH7 ...