![Hitachi RAC-50DH7 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/hitachi/rac-50dh7/rac-50dh7_service-manual_139700027.webp)
– 26 –
MAIN PARTS COMPONENT
THERMOSTAT (Room Temperature Thermistor)
Thermostat Specifications
FAN MOTOR
Fan Motor Specifications
CONNECTION
TEMPERATURE
°
C (
°
F)
INDICATION
16
INDICATION
24
INDICATION
32
MODEL
RAD-50DH7A/RAD-60DH7A/RAD-70DH7A
THERMOSTAT MODEL
IC
OPERATION MODE
COOL
HEAT
ON
15.6 (60.1)
20.0 (68.0)
OFF
15.3 (59.5)
20.7 (69.3)
ON
23.6 (74.5)
28.0 (82.4)
OFF
23.3 (73.9)
28.7 83.7)
ON
31.6 (88.9)
36.0 (96.8)
OFF
31.3 (88.3)
36.7 (98.1)
M
RED
BLK
WHT
YEL
BLU
280V
15V
0V
0 ~ 6.5V
FG
MODEL
RAD-50DH7A/RAD-60DH7A/RAD-70DH7A
POWER SOURCE
DC: 280V
DC350V
OUTPUT
56W
(Control circuit built in)
BLU : BLUE
YEL : YELLOW
BRN : BROWN
WHT : WHITE
GRY : GRAY
ORN : ORANGE
GRN : GREEN
RED : RED
BLK : BLACK
PNK : PINK
VIO : VIOLET
RED
360V
BLK
0V
WHT
15V
M
YEL
0~6V
BLU
0~15V
RAC-50DH7/RAC-60DH7/RAC-70DH7
80W
Содержание RAC-50DH7
Страница 30: ... 29 CIRCUIT DIAGRAM Wired Remote Control ...
Страница 31: ... 31 CIRCUIT DIAGRAM MODEL RAD 50DH7A RAD 60DH7A RAD 70DH7A ...
Страница 32: ... 33 CIRCUIT DIAGRAM MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 35: ... 39 51 53 53 55 57 49 29 66 Heating ...
Страница 76: ... 86 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 79: ... 89 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 82: ... 92 CHECKING THE REMOTE CONTROLLER ...
Страница 87: ... 97 16 ...
Страница 101: ...HITACHI PM NO 0411E Printed in Malaysia RAD 50DH7A RAC 50DH7 RAD 60DH7A RAC 60DH7 RAD 70DH7A RAC 70DH7 ...