![Hitachi RAC-50DH7 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/hitachi/rac-50dh7/rac-50dh7_service-manual_139700060.webp)
– 70 –
(4) During OFF
●
While IC1 is on, the following energy charges the primary windings of the transformer:
Energy=LI
2
/2. Here, L : Primary inductance
I : Current when IC1 is off
This energy discharges to the secondary windings during power off. That is, C707-C710, C718 is
charged according to the turn ratio of each winding.
●
At the start, an overcurrent flows to IC1 because of the charged current at C707-C710, C718.
●
The drain current at IC1 generates a voltage across R716. If it exceeds the IC1 base voltage, it sets the
IC gate voltage to “HI”.
●
R716 limits the gate voltage to prevent excessive collector current from flowing to IC1.
●
This SW power circuit uses a frequency as low as 20kHz, especially at a low load (when both the indoor
and outdoor units stop): This reduces power loss in standby status.
<Reference>
If the power circuit for P.W.B. seems to be faulty:
(1) Make sure that 5V, 12V, 15V, 17V and -5V on the control P.W.B. power voltage are the specified values.
(2) When only the 5V output is low:
REG 1 (regulator) faulty, 5V-0V shorted, output is too high, or REG 1 is abnormal.
(3) When 12V and 5V are abnormal:
The following defects can be considered:
1
Fan, operation, power, rush prevention relay (shorting in relay, etc.)
2
REG 1 (regulator is abnormal), etc.
Shorting on primary circuits.
When shorting occurs in the secondary circuits, there is no abnormality in the primary circuits because
of overcurrent protection.
The voltage rises when an opening occurs in the primary circuits, or the feedback system is abnormal.
(4) When 15V and 17V power supply are abnormal:
D710, D713 or Drive circuit is abnormal.
(5) When all voltage are abnormal:
IC1, R716, may possibly be defective. Also D cable may possibly be reverse connected.
If IC1 is abnormal, be aware that other components, such as the power module, REG (regulator), etc. are
possibly defective.
[When the switching power supply seems to be abnormal, the voltage between IC1 pin
4
(to be measured
at the leads of R701 and R702) and IC1 pin
5
(to be measured at R216 lead) may be between 11 and 16V.
This is because the protection circuit of IC
is operating.]
Содержание RAC-50DH7
Страница 30: ... 29 CIRCUIT DIAGRAM Wired Remote Control ...
Страница 31: ... 31 CIRCUIT DIAGRAM MODEL RAD 50DH7A RAD 60DH7A RAD 70DH7A ...
Страница 32: ... 33 CIRCUIT DIAGRAM MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 35: ... 39 51 53 53 55 57 49 29 66 Heating ...
Страница 76: ... 86 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Страница 79: ... 89 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 82: ... 92 CHECKING THE REMOTE CONTROLLER ...
Страница 87: ... 97 16 ...
Страница 101: ...HITACHI PM NO 0411E Printed in Malaysia RAD 50DH7A RAC 50DH7 RAD 60DH7A RAC 60DH7 RAD 70DH7A RAC 70DH7 ...