ENGLISH
8.10 INDIVIDUAL LOUVER SETTING
8.10.1 Setting
This setting is available only for the indoor unit adopting the
individual louver. Each louver angle can be set individually.
?
N O T E
• This function is available only when the indoor unit corresponds to the
individual louver.
• This function cannot be set when the unit is stopped.
• The fan speed changes to “LOW” while this function is being set.
(After the setting is completed, the unit operation returns to normal).
• As for “Start-up of Heating Operation”, “During Defrost Operation” and
“Activation of Thermo-Controller”, all the louver angles are fixed at
horizontal position automatically even when this function is activated.
• This function will not be available if two controllers (including a
combination of wired cont wireless controller) are used.
1
Select “Individual Louver Setting” from the “Menu” and press
“OK”.
The “Individual Louver Setting” menu will be displayed.
Menu
Function 15
Total Heat Exchanger SET
VENTI
Louver Open/Close
03
/
05
Individual Louver Setting
15:10(Fri)
Entr
Rtrn
Sel.
OK
OK
?
/
OK
?
/
2
Select “Individual Louver Setting” from the “Individual Louver
Setting” menu and press “OK”.
OK
Cancel INDV Louver SET
Individual Louver Setting
Individual Louver Setting
Entr
Rtrn
Sel.
OK
?
/
OK
?
/
?
N O T E
If the number of indoor units connected with the remote control is 1, the
screen passes directly to display the step 4 after this step.
3
Select the indoor unit to change the louver direction by
pressing “ ”, “ ”, “ ” or “
”. Press “OK”.
OK
Individual Louver Setting
01-01
01-02
01-03
Select unit to set.
01-04
Entr
Rtrn
Sel.
OK
?
/
OK
?
/
?
N O T E
The indoor unit displayed on the screen flashes if the individual louver is set.
4
Press “ ” or “ ” and select the louver from 1 to 4. The
selected louver is opened and the other louvers are closed.
OK
?
/
OK
?
/
OK
Individual Louver Setting:01-03
Adjust air direction & louver angle.
1
2
3
4
Entr
Rtrn
Sel.
Adj.
5
Select the louver angle by pressing “ ” or “
” and press “OK”.
OK
?
/
OK
?
/
OK
Individual Louver Setting:01-03
Adjust air direction & louver angle.
1
2
3
4
Entr
Rtrn
Sel.
Adj.
The louver angle will be changed as follows.
INDV
INDV
INDV
INDV
INDV
INDV
INDV
INDV
?
N O T E
The louver direction without “INDV” complies with the setting of the
normal mode.
6
The confirmation screen will be displayed.
Select “Yes” by pressing “ ” or “
” and press “OK”. The
setting is confirmed and the screen will return to the normal
mode.
OK
?
/
OK
?
/
OK
Individual Louver Setting:01-03
Yes
No
Sel.
Entr
Rtrn
Fix individual louver setting?
MENU OPERATION
PMML0496 rev.1 - 12/2020
53