4.8 AUTOMATIC COOLING/HEATING OPERATION
Automatically and according the indoor temperature the mode
changes as follow:
When mode is in cooling, the mode is change to heating if the
indoor temperature is the “heating setpoint” -1ºC.
When mode is in heating, the mode is changed to cooling if the
indoor temperature is the “cooling setpoint” +1ºC.
A/C
MODE
SPEED LOUV.
TEMP
AUTO
SPEED
Adj.
Meeting Room
?
N O T E
Optional function setting (b8=01) is needed for the use of automatic
cooling/heating operation.
4.9 AUTOMATIC COOLING/HEATING OPERATION DUAL SETPOINT
This function is available in standard air-to-air indoor units
and is used to switch between heating and cooling operation
automatically depending on a cooling set point and a heating set
point (dual set point).
When mode is in cooling, the mode is change to heating if the
indoor temperature is the “heating setpoint” - temperature set in
optional function r2.
When mode is in heating, the mode is changed to cooling if the
indoor temperature is the “cooling setpoint” + temperature set in
optional function r2.
A/C
MODE
LOUV.
AUTO
Meeting Room
Adj.
LOUV.
TEMP
SPEED
COOL
HEAT
HEAT TEMP
?
N O T E
Optional function setting (r1=01) is needed for the use of automatic
cooling/heating operation and changing AUTO COOL/HEAT temperature.
4.10 OPERATION LOCK
• This function is used to lock the setting from the remote
control switch.
• The following functions are locked:
a.
Operation Mode (MODE)
b.
Temperature Setting (TEMP)
c.
Fan Speed (SPEED)
d.
Swing Louver Direction (LOUV)
1
Setting of the operation lock, press “
” and “
?
/
” (return /
help) simultaneously for 3 seconds. The icon of “ ” will be
turned ON. Even when “
” or “
” is pressed, locked setting
items will be skipped.
A/C
MODE SPEED
TEMP
COOL
Meeting Room
SPEED
ADJ
OK
?
/
2
Cancellation of the operation lock, press “
” and “
?
/
” (return
/ help) simultaneously for 3 seconds. “ ” will be turned OFF,
and operation lock will be cancelled.
OK
?
/
A/C
MODE SPEED
TEMP
COOL
SPEED
ADJ
Meeting Room
?
N O T E
• Every time pressing “ ” and “
?
/
” (return / help) simultaneously for
3 seconds, the operation lock state will be switched alternately to
locked/unlocked.
• In order to avoid the lock Set the optional functions to unlock
individually the mode selection (F8=00), temperature setting (F9=00),
speed selection (FA=00) or swing louver operation (Fb=00).
• Set the corresponding optional function, “mode(F8=00)”, “temperature
setting (F9=00)”, “speed selection (FA=00)” or “swing louver operation
(Fb=00)” in order to avoid the lock of any of them.
• In order to avoid the lock of any function set to “00” the corresponding
optional function:
-
(F8=00) for the mode selection
-
(F9=00) for temperature setting
-
(FA=00) for the speed selection
-
(Fb=00) for the swing louver operation
OPERATION METHOD