--- 31 ---
(b) Reassembly
Reassembly can be accomplished by following the disassembly procedures in reverse. However, particular
attention should be given to the following items.
Prior to reassembly, thoroughly remove any foreign matter from the pawl groove of the Nail Guide
[90]
.
Before tightening the Nylock Hex. Socket Hd. Bolt M4 x 10
[94]
, thoroughly remove any grease from the
threaded portion of the Nail Guide
[90]
.
After reassembly, push Nail Stoppers (B)
[91]
with a finger, and confirm that they return smoothly.
10. INSPECTION AND CONFIRMATION AFTER REASSEMBLY
Ensure that Plunger (A)
[66]
moves smoothly.
Push Nail Stopper (B)
[91]
with a finger and confirm that they return properly.
Ensure there is no air leakage from each section.
Check that the feed piston operates properly when the machine is operated with an air pressure of 4.9 bar
(5 kgf/cm
2
, 70 psi). (Conduct check under idle operation, with the nail guide open.)
Check that there is no idle operation or bent nails when nails are driven with an air pressure of 4.9 bar
(5 kgf/cm
2
, 70 psi).
Reconfirm proper tightening torques of bolts and screws in every section.
NOTE: When performing idle operation, turn the adjuster to its maximum (deepest) driving position.
Confirm that the pushing lever slides smoothly.
Confirm that the machine will not operate when the trigger is pulled, and that it will not operate when the
pushing lever is pushed upward.