![Hitachi NV 50AG2 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/hitachi/nv-50ag2/nv-50ag2_technical-data-and-service-manual_143712020.webp)
--- 18 ---
Disassemble the control valve
section to check the O-rings
of plunger (A) and valve
piston (B).
Check for the abnormality
(wear, damage and/or
deformation) in each part.
Check where the single shot/
continuous shot change knob
is positioned.
* The O-ring of plunger (A)
is worn.
* The O-ring of valve piston
(B) is worn.
The sliding face of plunger
(A) of valve piston (B) is
abnormal (seized and/or
deformed).
Plunger (A), trigger (A) and
pushing lever (B) are
abnormal (worn and/or
deformed).
The single shot/continuous
shot switch lever is
positioned incorrectly.
Fault
Cause
(The mark * refers to main causes.)
Inspection method
Remedy
Replace the abnormal parts.
Set the single shot/continous
shot change knob to a correct
position.
(5)
Single
shot is
impossible.
Содержание NV 50AG2