NOTE : • There are the rail (R) and the rail (L). Check that with the marking on the rail.
• These rails extend or shorten back and forth
• There are the rail type with a stopper and the rail type without a stopper.
(1) Insert the pins on the front and back of the rail (R) into the holes on the front and back of the rack
and clip them with rail clips to fix. The pin positions are the first and third holes from the bottom
of the unit boundary line on the rack for both front and back.
(2) Fix the rear side of the rail (R) with binding screw (M5
×
10) and loop cable tie. The fixing
position is the third hole from the bottom of the unit boundary line.
(3) For the rail type with a stopper, slide the stopper to the rear side of the rack frame (see
(4) Install the rail (L) in the rack in the same way.
Figure 3-15 Installing Rails for HSNBX (without Stopper)
Rack frame (rear side)
Binding screw(M5
×
10)
Clip
Pin
Clip
Pin
Rail (R)
Rack frame
(front side)
Unit boundary
Unit boundary
Unit boundary
Unit boundary
Pin
Pin
Loop cable tie