Copyright © 2019, 2021, Hitachi, Ltd.
DKC910I
Hitachi Proprietary
[INST(IN)13-02-10]
Rev.0
INST(IN)13-02-10
13.2 Attachment/Removal Procedure of Maintenance PC
1. Attachment Procedure of Maintenance PC
(1) Remove the Front Bezel from HSNBX-0 or HSNBX-1. (Refer to
(2) Connect the power cable and LAN cable to the Maintenance PC.
(3) Connect the LAN cable to CONSOLE port of the SSVP0 (SVP-BASIC side). (Refer to
When replacing SSVP0, perform either of the following:
• When the SVP High Reliability Kit is installed, connect the LAN cable to the CONSOLE port on
SSVP1 (next to SVP-OPTION).
• When the SVP High Reliability Kit is not installed, connect the LAN cable to the CONSOLE port
on SSVP0 (next to SVP-BASIC).
(4) Connect the power cable to the power supply.
(5) Power on the Maintenance PC.
(6) After Windows is started, perform the remote desktop connection of the Maintenance PC to the
SVP using the connection utility. (For details, see
.)
If the remote desktop connection to the SVP fails, perform either of the following:
• When the SVP High Reliability Kit is installed:
Connect the LAN cable to the CONSOLE port on SSVP1 (next to SVP-OPTION), and then retry
the remote desktop connection. If the remote desktop connection fails again, perform the recovery
procedure described in
“
When Connection to SVP (Remote Computer) Cannot Be Made
”
• When the SVP High Reliability Kit is not installed:
Perform the recovery procedure described in
“
When Connection to SVP (Remote Computer)
Cannot Be Made
”