2. Pull all the Fibre Channel cables into the rack frame passing them through an opening for cables on the
bottom plate of the rack frame.
3. Connect the Fibre Channel cable to the connector of the each port.
NOTE : • Insert the Fibre Channel
cables until they are fixed to the Small Form-Factor
Pluggable (SFP).
If the Fibre Channel cables are inserted half in the Small Form-Factor Pluggable
(SFP), the Controller Board continues to detect the Fibre Channel cable failures, and
the I/O processing of the Controller Board may be deteriorated.
• The location of Fibre Channel cable
connectors is different depending on Controller
Board. Check the location before connecting a cable.
• Check that Fibre Channel cable latch clicks and the cables are surely connected.
4. Fix the Fibre Channel cables with binders giving them excessive lengths.
If the length of the Fibre Channel cables is too long, put the extra cable length outside the rack.
Figure 9-6 Optical Fibre Channel Routing in the RKU Rack Frame
Cable passing opening
Fibre Channel cables
DKC
Rear view of Rack Frame
Binder