Copyright © 2019, 2021, Hitachi, Ltd.
DKC910I
Hitachi Proprietary
[INST(IN)14-01-80]
Rev.0.1
INST(IN)14-01-80
*1 : Even if the
“
IP Address
”
is
“
126.255.254.15
”
and the
“
Subnet Mask
”
is
“
255.0.0.0
”
on the screen of
“
Set IP Address
”
, be sure to select
“
OK
”
and reply
“
OK
”
to the message
“
This will reboot SVP.
”
.
*2 : It
ʼ
s necessary to execute the procedure of
“
SIM Log Complete
”
before deleting the SIM data.
*3: Press the following keys at the same time to change the mode to
“
Initial Setting
”
.
[SHIFT], [CTRL], [I]
And input the password. (*5)
*4: Also,
“
IP Address
”
should be specified as follows:
(1) Specifying the IP Address according to the DKC Serial Number Select
“
Based on Serial
Number
”
, and the IP Address will be assigned automatically.
(2) Specifying in option
Select
“
Specified
”
and specify the optional address for the IP Address.
*5: For the password, ask the technical support division. And use it with their approval.
*6: The SIM = bf85a3 (Basic SVP: SVP RAS Switch#1 remains (SVP PS ON/OFF INH SW)) may
be reported. When the SVP high-reliability kit is installed, the SIM = bf86a3 (Optional SVP: SVP
RAS Switch#1 remains (SVP PS ON/OFF INH SW)), bfe3a2 (SVP duplication setting defect) and
7ff201 (standby SVP failure detection) may occur but there is no problem because they occur in
process of the SVP replacement.
*7: Select [All Microprograms] and click [OK].