5
Installation Location
The unit must be installed on a solid level surface
on a concrete pad foundation not connected to the
house foundation. Rubber cushions can be added to
reduce vibration and noise if required.
The unit should be place so that it is well away
from bedrooms or noise sensitive areas including
neighbour’s section boundaries. (The unit will
produce noise that is above the minimum 45
decibel rating).
The unit should be well ventilated with no
obstructions and kept level at all times.
Ensure there is good drainage around installation
area and make sure this water cannot run out onto
paths as it may cause ice or slime build up which is
undesirable. (The unit can produce large volumes
of condensation water when running in high
humidity zones. There is also a large run off when
the unit melts ice during a defrost cycle).
Avoid locations exposed to machine oil vapour,
salty air, thermal springs sulphur gases or other
harsh substances
If operation in temperatures below 0°C for
prolonged periods or locations where the snow may
fall the unit must be raised at least 300mm off the
ground. This is necessary to avoid ice build-up on
the unit’s chassis.
The unit must be installed level in both axes (less
than 2mm tolerance per meter)
Locations exposed to strong winds should be
avoided otherwise baffles may be necessary to
deflect strong winds and to prevent snow from
blowing directly into the unit. They must not
restrict air flow into the unit.
Keep suitable distance between the unit and the
building to ensure the normal running of the unit
and enough room is available for maintenance.