Operating Precautions
11
Using a CF Card/USB flash drive
• Inserting a CF card/USB flash drive upside down, backwards or in the
wrong direction may damage the CF card, USB flash drive, or HiLogger.
• Never eject a CF card /USB flash drive while measuring or when the
HiLogger is or accessing the card. Data on the CF card/USB flash
drive may be destroyed. (The CF icon/USB flash drive icon at the
lower right is red while the card is being accessed.)
• Do not transport the HiLogger while a USB flash drive is connected.
Damage could result.
• As the CF card/USB flash drive is sensitive to static electricity, damage
to the CF card/USB flash drive or wrong operations by the HiLogger
may occur due to static electricity. Please be careful when handling it.
• With some USB flash drives, the HiLogger may not start up if power is
turned on while the USB flash drive is inserted. In such a case, turn
power on first, and then insert the USB flash drive. It is recommended
to try out operation with a USB flash drive before starting to use it for
actual measurements.
• The Flash memory in a CF card/USB flash drive has a limited operat-
ing life. After long-term usage, data storage and retrieval become diffi-
cult. In this case, replace the CF card/USB flash drive with a new one.
• We cannot provide compensation for data loss in a CF card/USB flash
drive, regardless of content or cause of the damage. Data is also cleared
from memory if a long time passes after measuring. Always maintain a
backup of important data stored on a CF card/USB flash drive.
• Although real-time saving to USB flash drive is supported, a CF card is
recommended for data preservation. Performance cannot be guaranteed
when using storage media other than a Hioki-specified CF card option.
• Use a USB flash drive whose continuous current consumption does not
exceed 300 mA (peak 500 mA). (The peak value is displayed as "Max
Power" under the USB flash drive self-test on the [System] screen.)
• Depending on how USB is used, the USB connector and instrument set-
tings may vary as shown in the chart below.
• The three USB methods of use described in the chart below involve
exclusive settings and cannot be used simultaneously.
USB method of use
Connector
used
[System] screen USB
mode setting
Use a USB flash drive.
Type A
USB Memory (Default)
Communicate with the LR8431-20
and initiate measurement using the
Logger Utility software from a com-
puter (using a USB cable).
Type B
USB Communication
Read files on a CF card that is con-
nected to the LR8431-20 from a
computer (using a USB cable).
Type B
USB Drive
Содержание LR8431
Страница 1: ...EN LR8431 20 MEMORY HiLOGGER Instruction Manual Aug 2015 Revised edition 3 LR8431B980 03 15 08H...
Страница 2: ......
Страница 20: ...Operating Precautions 12...
Страница 44: ...2 5 Zero Adjustment 36...
Страница 74: ...3 7 Viewing All Channel Settings in a List 66...
Страница 88: ...4 5 About Recording Operation 80...
Страница 120: ...6 6 Transferring Data to a Computer USB Drive Mode 112...
Страница 126: ...7 2 Numerical Value Calculation Expressions 118...
Страница 136: ...8 3 Making System Settings 128...
Страница 144: ...9 5 Synchronous Measurements with Multiple Instruments 136...
Страница 154: ...Chapter 10 Specifications 146...
Страница 198: ...Appendix 11 Pulse Input Circuit Diagram A40...
Страница 202: ...Index Index 4...
Страница 203: ......
Страница 204: ...EN LR8431 20 MEMORY HiLOGGER Instruction Manual Aug 2015 Revised edition 3 LR8431B980 03 15 08H...