1.3 Names and Functions of Parts
10
Lit when measuring
voltage.
Indicates percentage
units during relative
value comparator op-
eration.
Shows measured
value or setting item.
Main display
(Upper row)
AUTO
Lit when measuring with Auto-Ranging.
FAST, MED, SLOW
The selected Sampling Rate is lit.
0 ADJ
Lit when measuring in a range for
which Zero-Adjustment has been per-
formed.
MEM
Lit when the Memory function is en-
abled.
EXT TRIG
Lit when the External Trigger function
is enabled.
(Lower row)
V
Lit when the
V (Resistance and
Voltage measurement) mode is se-
lected.
STAT
Lit when the Statistical Calculation
function is enabled.
AVG
Lit when measuring with the Averag-
ing setting enabled.
LOCK
Lit when the keys are locked.
REMOTE
Lit during communications.
The current measurement mode is indicated while measuring, and the setting item is displayed while
making settings.
Shows Comparator Decision Result.
Hi
Indicates that the measured value is
above the upper threshold.
IN
Indicates that the measured value is be-
tween the upper and lower thresholds.
Lo
Indicates that the measured value is be-
low the lower threshold.
Units of displayed measurement
V
Unit of voltage
Unit of resistance (lit when the 3
to 3000
range is selected)
m
Unit of resistance (lit when the 3
m
300 m
range is select-
ed)
Indicates Voltage mea-
surement mode
Indicates percentage
units during relative value
comparator operation
While measuring, indi-
cates the Comparator
function is enabled.
HIGH, LOW
Indicates that absolute value comparator operation is enabled
(while measuring), and also when setting.
REF, %
Indicates that relative value comparator operation is enabled
(while measuring), and also when setting.
V
Indicates the measured voltage value unit.
Upper and lower thresholds and other settings are displayed (when set).
Sub display
HIOKI BT3564A961-02
Содержание BT3564
Страница 2: ...HIOKI BT3564A961 02...
Страница 44: ...3 7 Displaying Measurement Results 38 HIOKI BT3564A961 02...
Страница 80: ...4 12 Reset Function 74 HIOKI BT3564A961 02...
Страница 89: ...5 4 Internal Circuitry 83 5 Chapter 5 External Control EXT I O 5 4 Internal Circuitry HIOKI BT3564A961 02...
Страница 98: ...6 3 Printing 92 HIOKI BT3564A961 02...
Страница 170: ...8 8 Sample Programs 164 HIOKI BT3564A961 02...
Страница 182: ...10 3 Error Indication 176 HIOKI BT3564A961 02...