Moldboard Problems 13
PLOW CONSTANTLY ANGLES RIGHT
Locate right hydraulic solenoid (See Power Unit Drawing).
Check if constantly on (See Hydraulic Solenoid Test Procedure).
IS RIGHT SOLENOID CONSTANTLY ON?
No.
Yes.
|
Perform Controller Test Procedure.
|
DID CONTROLLER TEST OK?
|
No.
Yes.
|
|
Perform Under Hood Harness Test Procedure.
|
|
DID UNDER HOOD HARNESS TEST OK?
|
|
No.
Yes.
|
|
|
Perform Plow Harness Test Procedure.
|
|
|
DID PLOW HARNESS TEST OK?
|
|
|
No.
Yes.
|
|
|
|
See Special Problems.
|
|
|
|
|
|
|
Check ORANGE wire between J1 - 4 (plow harness ) & right solenoid
|
|
|
for short to +12.
|
|
|
DID THIS FIND THE PROBLEM?
|
|
|
No.
Yes, done.
|
|
|
|
|
|
|
See Special Problems.
|
|
|
|
|
Check wiring between P2 - 6 (controller) to P1 - 4 (grill) for short to +12.
|
|
Note:
Wire color changes from BLUE between P2 - 6 & Relay Box,
|
|
to ORANGE between Relay Box & P1 - 4.
|
|
DID THIS SOLVE THE PROBLEM?
|
|
No.
Yes, done.
|
|
|
|
|
See Special Problems.
|
|
|
Replace the controller.
|
Hydraulic problem (See Hydraulic Unit Service Manual).