72 Reference
RED
BLACK
MOTOR
TANK
PLOW HARNESS
ORANGE
PLOW HARNESS
GREEN
C
D
VOLTAGE SPIKE SUPPRESSOR
A
BROWN PLOW HARNESS
B
TYP C & D
DWG NO. 3798A
HYDRAULIC SOLENOID SPIKE SUPPRESSORS
The following drawing shows the installation of
the hydraulic solenoid spike suppressors. Note
that the large ring terminal is the positive end
of the diodes and is attached to point A, which
is the ground connection of the hydraulic power
unit. The remaining terminals are the negative
ends of the diodes.
The small ring terminal is attached to point B,
the #10-32 stud on the solenoid along with the
brown control wire. The remaining two piggy-
back terminals are attached to points C and D
with the orange and green control wires. The two
terminals are interchangeable.
DWG NO. 4090
3 DIOE SPIKE SUPPRESSOR PCB
Internal Spike Suppressors
Starting with model year 2000 plows, the hy-
draulic solenoid spike suppression diodes were
mounted on the wire splice PCB located in the
plow harness. The PCB was also incorporated
into any model year 1996 - 1999 replacement
plow harnesses.
Also starting with the model year 2000, the mo-
tor solenoid spike suppression diode was built
into the under hood harness. Model year 1996
- 1999 plows still need to rely on the suppression
diode mounted on the motor solenoid.