66 Reference
SOLENOID TABLE
DOWN
S3
LEFT
RIGHT
S2
S1
DWG NO. 3980
POWER UNIT DRAWING
The following table provides information on the
various solenoids used for each moldboard
movement. The table can be read from left to
right to see, for example, that the Motor solenoid
is on for Up, Left, and Right moldboard move-
ments. The table can also be read from top to
bottom to see, for example, that a Left mold-
board movement requires the Motor and Left
solenoid.
The table also shows the connections for the so-
lenoid signals from the Controller, through the
Under Hood harness, to the Plow harness. As an
example, the Left solenoid signal comes out of
the Controller on J2 - 5. It enters the Under Hood
harness on P2 - 5 and exits it on P1 - 5. It then
enters the Plow harness on J1 -5 and goes to
the Left solenoid. The P and J connector desig-
nators refer to the System Schematic at the end
of this section.
Solenoids
Used
Moldboard Movements
Connections
Up
Down
Left
Right
Controller
Under Hood
Plow
Motor
ON
ON
ON
J2-1
P2-1
N/C
N/C
Left
ON
J2-5
P2-5
P1-5
J1-5
Right
ON
J2-6
P2-6
P1-4
J1-4
Down
ON
J2-2
P2-2
P1-3
J1-3