DS-720xHTI-Kx DVR User Manual
UM DS-720xHTI-Kx 012918NA
49
The speed dome starts linear scan from the left limit to the right limit, and you must set the left limit
to the left side of the right limit. Also, the angle from the left limit to the right limit should be no more
than 180º.
4.2.8 Calling Linear Scan
Purpose
Follow the procedure to call the linear scan in the predefined scan range.
1.
Click
PTZ
in the lower-right corner of the
PTZ Settings
interface, or press
PTZ
on the front panel, or click
the PTZ Control icon
in the quick setting bar to enter the PTZ setting menu in live view mode.
2.
Click the
One-touch
tab to show the one-touch function of the PTZ control.
Figure 4-12
PTZ Panel – One-touch
3.
Click
Linear Scan
to start the linear scan and click
Linear Scan
again to stop it.
4.
You can click
Restore
to clear the defined left limit and right limit data. The dome needs to reboot to
for settings to take effect.
4.2.9 One-Touch Park
Purpose
Configure settings to start a predefined park action (scan, preset, patrol, etc.) automatically after a period
of inactivity (park time).
1.
Click
PTZ
in the lower-right corner of the
PTZ Settings
interface, or press
PTZ
on the front panel, or click
the PTZ Control icon
in the quick setting bar to enter the PTZ setting menu in live view mode.
2.
Click the
One-touch