8.5.1 Set Burst Frame Count
Under external trigger mode, you can set burst frame count. Click Acquisition Control >
Acquisition Burst Frame Count, enter Acquisition Burst Frame Count, and its range is from 1 to
1023.
Figure 8-12
Set Burst Frame Count
When Acquisition Burst Frame Count is 1, it is in single frame trigger mode. When Acquisition
Burst Frame Count is larger than 1, it is in multi-frame trigger mode.
If Acquisition Burst Frame Count is n and when inputting 1 trigger signal, the camera stops
acquiring images after exposing n times and outputs n frame images. The sequence diagram of
burst frame count is shown below.
Trigger
Sensor
exposure
Burst Count = 4
Figure 8-13
Sequence Diagram of Burst Frame Count
Here we take the rising edge as the trigger signal.