Click Trigger Selector > Trigger Source, and select Trigger Source according to actual demands.
Figure 8-4
Set External Trigger Source
8.4.2 Set Software Trigger
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select On as Trigger Mode.
3.
Select Software as Trigger Source, and click Execute in Trigger Software to send trigger
commands.
Figure 8-5
Set Software Trigger
8.4.3 Set Hardware Trigger
The camera has one opto-isolated input (Line 0), and one bi-directional I/O (Line 2) that can be
configured as input signal.
Here we take Line 2 as an example to introduce the hardware trigger settings. You select Line 0 or
Line 2 as trigger source to set hardware trigger according to actual demands.