CoaXPress Area Scan Camera
·
User Manual
35
When the Strobe Line Duration value is 0, the strobe duration is equal to the exposure time. When
the Strobe Line Duration value is not 0, the strobe duration is equal to Strobe Line Duration value.
Set Strobe Line Delay
The camera supports setting strobe line delay to meet actual demands. When exposure starts, the
strobe output does not take effect immediately. Instead, the strobe output will delay according to
the strobe line delay setting.
Click Digital IO Control > Strobe Line Delay, and enter Strobe Line Delay according to actual
demands.
Figure 9-6
Set Strobe Line Delay
The sequence diagram of strobe line delay is shown below.
Strobe
Trigger_in 1
Sensor
Exposure
Exposure
1
Exposure
2
Exposure
3
Strobe
delay
Trigger_in 2
Trigger
delay
Trigger_in 3
Trigger
delay
Duration
Trigger
delay
Figure 9-7
Sequence Diagram of Strobe Line Delay
Set Strobe Line Pre Delay
The camera also supports the function of strobe line pre delay, which means that the strobe signal
takes effect early than exposure. This function is applied to the external devices that have slow
response speed.
Click Digital IO Control > Strobe Line Pre Delay, and enter Strobe Line Pre Delay according to
actual demands.
Содержание CoaXPress
Страница 1: ...CoaXPress Area Scan Camera User Manual ...
Страница 10: ...CoaXPress Area Scan Camera User Manual x Appendix A Camera Parameter Index 85 ...
Страница 41: ...CoaXPress Area Scan Camera User Manual 31 Figure 8 18 Set Trigger Debouncer ...
Страница 82: ...CoaXPress Area Scan Camera User Manual 72 Figure 11 39 Other Corrections ...
Страница 102: ...UD26060B ...