CoaXPress Area Scan Camera
·
User Manual
30
Trigger Activation Parameter
Parameter Value Principle
Any Edge
Acquisition Control >
Trigger Activation
Any Edge
If level signal given by external devices
is in rising or falling edge, the camera
receives the trigger signal and starts
acquisition.
Level High
Acquisition Control >
Trigger Activation
Level High
If level signal given by external devices
is in level high, the camera is in image
acquisition status.
Level Low
Acquisition Control >
Trigger Activation
Level Low
If level signal given by external devices
is in level low, the camera is in image
acquisition status.
8.5.5 Set Trigger Debouncer
The external trigger input signal of the camera may have signal bounce that may cause false trigger.
Thus, it is necessary to debounce the external trigger signal, and its sequence diagram is shown
below.
Figure 8-17
Trigger Debouncer Sequence Diagram
Here we take the rising edge as the trigger signal.
Click Digital IO Control > Line Debouncer Time, enter Line Debouncer Time, and its range is from
1 μs to 1000000 μs.