CoaXPress Area Scan Camera
·
User Manual
34
No. Name
Description
7
Soft Trigger Out
It refers to output one I/O edge signal when software trigger
acquisition.
8
Hard Trigger Active
It refers to output one I/O edge signal when hardware trigger
acquisition.
9
Count Active
It refers to output one I/O edge signal when counter output is
enabled.
10
Timer Active
It refers to output one I/O edge signal when timer output is
enabled.
If Timer Active is selected as Line Source, you can set Strobe Line Duration and Strobe Line Delay,
and the camera will output signal correspondingly after click Execute in Line Trigger Software.
Figure 9-4
Set Timer Active
Regarding strobe signal, you can also set its duration, delay and pre delay.
Set Strobe Line Duration
After enabling strobe signal, you can set its duration. Click Digital IO Control > Strobe Line
Duration, and enter Strobe Line Duration.
Figure 9-5
Set Strobe Line Duration