CoaXPress Area Scan Camera
·
User Manual
21
Off refers to the internal trigger mode and On refers to the external trigger mode.
8.4 External Trigger Mode
8.4.1 Set External Trigger Source
There are 5 types of external trigger sources, including software trigger, hardware trigger, counter
trigger, link trigger, and free trigger.
External trigger source may differ by camera models.
These 5 trigger sources are valid only when the Trigger Mode is On.
Table 8-1
Principle and Parameter of External Trigger Mode
External Trigger
Source
Parameter
Parameter Value
Principle
Software Trigger
Acquisition Control >
Trigger Selector >
Trigger Source
Software
The software sends trigger signal
to the camera via CoaXPress
interface to acquire images.
Hardware Trigger
Acquisition Control >
Trigger Selector >
Trigger Source
Line 0, Line 2
External device connects camera
via camera I/O interface. External
device sends trigger signal to
camera to acquire images.
Counter Trigger
Acquisition Control >
Trigger Selector >
Trigger Source
Counter 0
The counter sends trigger signal
to the camera to acquire images.
Link Trigger
Acquisition Control >
Trigger Selector >
Trigger Source
Link Trigger 0
The frame grabber sends trigger
signal to the camera to acquire
images.
Free Trigger
Acquisition Control >
Trigger Selector >
Trigger Source
Anyway
Use software trigger, hardware
trigger, and link trigger to send
signals to the camera to acquire
images.
Содержание CoaXPress
Страница 1: ...CoaXPress Area Scan Camera User Manual ...
Страница 10: ...CoaXPress Area Scan Camera User Manual x Appendix A Camera Parameter Index 85 ...
Страница 41: ...CoaXPress Area Scan Camera User Manual 31 Figure 8 18 Set Trigger Debouncer ...
Страница 82: ...CoaXPress Area Scan Camera User Manual 72 Figure 11 39 Other Corrections ...