CoaXPress Area Scan Camera
·
User Manual
37
Chapter 10 I/O Electrical Feature and Wiring
10.1 I/O Electrical Feature
10.1.1 Line 0 Opto-isolated Input Circuit
The Line 0 opto-isolated input circuit in camera I/O control is shown below.
Line 0+
GPI
Line 0-
VCC
Figure 10-1
Line 0 Internal Circuit
The maximum input current of Line 0 is 25 mA.
Logic 1
Input Level
Logic 0
Input Level
Internal Logic
TDR
TDF
Figure 10-2
Input Logic Level