CoaXPress Area Scan Camera
·
User Manual
40
Line 2
GPI
GPO
VCC
Figure 10-5
Line 2 Bi-direction I/O Circuit
Line 2 Configured as Input
With the condition of 100 Ω and 5 VDC, the logic level and electrical feature of configuring Line 2
as output are shown below.
Logic 1
Input Level
Logic 0
Input Level
Internal Logic
TDR
TDF
Figure 10-6
Input Logic Level
Table 10-4
Electrical Feature of Line 2 Input
Parameter Name
Parameter Symbol
Value
Input Logic Level Low
VL
0 VDC to 0.3 VDC
Input Logic Level High
VH
3.3 VDC to 24 VDC
Input Rising Time
TDR
< 1 μs
Input Falling Time
TDF
< 1 μs
Make sure the input voltage is not from 0.3 VDC to 3.3 VDC as the electric status between
these two values are not stable.