P l e a s e G i v e P a r t N o . , D e s c r i p t i o n a n d U n i t S e r i a l N o .
HIGHWAY EQUIPMENT COMPANY
10
89008-A
Page Rev. A
INSTALLATION INSTRUCTIONS CONTINUED
SPINNER SENSOR
The spinner sensor must be mounted under the right-hand spinner disc in the holes provided. Rotate the
disc so that one of the cap screws is directly above the sensor. Position the sensor 1/8-inch or less
below the cap screw and tighten the sensor hardware. If the distance between the sensor and the spinner
cap screw is more than 1/8 inch, the sensor may net get a good RPM reading.
RADAR
The mounting of the radar unit will vary with the type of vehicle. The mounting kit supplied uses an
"L" shaped bracket and mounting plate. There is also a plate mounting bracket drawing that can be used
to fabricate a bolt-on version. Refer to the installation instructions included with the radar for more
information.
The radar should be mounted facing rearward and at a 35
°
angle horizontally. (Figure 2)
Figure 2 - Radar Mounting Angle
If at anytime an arc welder is used on the vehicle or anything connected to the
vehicle, be sure to connect the welders ground directly to one of the two items
being welded. Disconnect power cable from the Mark series control box! Failure
to do so can result in damage to components on both the vehicle and spreader in
which case the warranty will be null and void by manufacturer of same.
IMPORTANT!
Содержание New Leader MARK V DGPS-Ready