P l e a s e G i v e P a r t N o . , D e s c r i p t i o n a n d U n i t S e r i a l N o .
HIGHWAY EQUIPMENT COMPANY
13
89008-A
Page Rev. A
CONSOLE OVERVIEW CONTINUED
The choices of the display lines include:
Rate
- Displays application rate. Up/down arrows at the right of the display line indicate the rate can be
changed. Select the line and use the Arrow keys to change the rate.
Ground Speed
– Displays truck speed using a radar or GPS signal. Also displays selected manual
speed.
Spinner Speed
– Displays actual spinner speed. Up/down arrows at the right of the display line indicate
the spinner speed can be changed. Select the line and use the Arrow keys to change the speed. The
target rate for the job setting is displayed at the left. Note: Changing the spinner speed with the Mark
V console requires an optional PWM spinner valve.
Total Applied –
Displays total amount of material applied. Reset to zero using the Menu Selection key
under Clear.
Area Applied –
Displays total area applied. Reset to zero using the Menu Selection key under Clear.
Conveyor RPM –
Displays the conveyor revolutions per minute.
Lightbar Pass# -
Displays pass number and direction from A-B line when optional DGPS is connected.
Line can be selected to change the pass number or direction using the Menu Selection Arrow keys. See
your DGPS & Lightbar Manual for further information. [Note: Do not display this item if a DGPS
system is not connected.]
CABLE CONNECTIONS:
Figure 5
Main Port –
Power and
sensors
Port 1 – Connects
to remote device or
to computer for
firmware upgrade.
Aux 2
Port –
Valve
control
signals
Aux 1 Port –
DGPS5000
Содержание New Leader MARK V DGPS-Ready