background image

                     

P l e a s e   G i v e   P a r t   N o . ,   D e s c r i p t i o n   a n d   U n i t   S e r i a l   N o .

HIGHWAY EQUIPMENT COMPANY

19

89008-A

Page Rev. A

CALIBRATION AND MACHINE SETTINGS CONTINUED

Distance Calibration: Radar

NOTE:  A job must be active to calibrate radar.

From the main screen, press the SETUP key.  Press the CAL RADAR key.  The screen in Figure 7
appears.

a)

 

Find a good place to travel back and forth in a straight line.  Measure and mark off a travel distance.
A minimum distance of 200 feet is required.

b)

 

Press the Display Selection key next to the display line for “Actual Distance”.  A box should appear
around the display line.  By pressing the Up or Down Arrow keys, set the “Actual Distance” to equal
the distance you marked off.

c)

 

Position the vehicle at the beginning of the marked off distance.

d)

 

Press START TRAVEL key and drive vehicle to the end of the marked off distance.  Stop at the end
marker.

e)

 

Press STOP TRAVEL key.

f)

 

Press PERFORM CAL key.

g)

 

Repeat steps c-e to verify the displayed “Measured Distance” equals the “Actual Distance”.  If not,
repeat the calibration.

h)

 

Press EXIT key.

i)

 

Press the Menu Key 

to return to the main screen.

j)

 

Traveling in a straight line, verify the displayed “Ground Speed” on main screen is correct.

DISTANCE CALIBRATION: RADAR

ACTUAL DISTANCE:                                 

200

 ft

MEASURED DISTANCE:                                   

0

   ft

PULSES / 100 FT:                                  

2000

  ft

START

TRAVEL

CLEAR

DISTANCE

PERFORM

CAL

EXIT

Figure 7

Содержание New Leader MARK V DGPS-Ready

Страница 1: ...EDAR RAPIDS IOWA 52404 7052 PH 319 363 8281 www highwayequipment com FAX 319 632 3081 HIGHWAY EQUIPMENT COMPANY GENERAL MANUAL FOR MODEL MARK V DGPS READY SAFETY GUIDELINES INSTALLATION OPERATION TROU...

Страница 2: ......

Страница 3: ...AL NUMBER__________________ MANUAL NUMBER 89008 A EFFECTIVE 9 2002 HIGHWAY EQUIPMENT COMPANY 1330 76TH AVE SW CEDAR RAPIDS IOWA 52404 7052 PHONE 319 363 8281 FAX 319 632 3081 www highwayequipment com...

Страница 4: ...6 General Description 8 Installation Instructions 9 Console Overview 11 Calibration Machine Settings 14 Programming a Job 22 Operating Procedures 29 Troubleshooting 35 Instructions for Ordering Parts...

Страница 5: ...e warranty period shall not be extended beyond the original warranty period If you fail to return the warranty registration card or warranty card information as provided above to Highway within thirty...

Страница 6: ...ct Support Department at 319 363 8281 It has been our experience that by following these installation instructions and by observing the operation of the spreader you will have sufficient understanding...

Страница 7: ...concerning these guidelines please call your authorized dealer or our factory at 319 363 8281 Is used for informational purposes in areas which may involve damage or deterioration to equipment but ge...

Страница 8: ...curs Regardless of the care used in the design and construction of any type of equipment there are many conditions that cannot be completely safeguarded against without interfering with reasonable acc...

Страница 9: ...adhere to these 3 Remove the Liner A small bend at the corner or edge will cause the liner to separate from the decal Pull the liner away in a continuous motion at a 180 degree angle If the liner is s...

Страница 10: ...onveyor speed and product applied is easily accessed and customer configurable Rates can be entered manually or received via a serial port RS 232 connection to a remote device reading a prescription r...

Страница 11: ...y radios as possible Mount the interface module in a suitable location that is out of the way of the operator Allow room for cable service loops After mounting all other system components connect cont...

Страница 12: ...h the type of vehicle The mounting kit supplied uses an L shaped bracket and mounting plate There is also a plate mounting bracket drawing that can be used to fabricate a bolt on version Refer to the...

Страница 13: ...l Figure 3 Power Switch Selects power ON and OFF O for the console Conveyor Switch Turns the main conveyor ON green and OFF red Menu Key Used to exit setup screen or advance menu display Menu Selectio...

Страница 14: ...in the menu selection area Pressing the Menu Selection Arrow keys scroll the menu to display new choices To select a new display item press the Menu Selection Key below the item you want to view This...

Страница 15: ...displayed at the left Note Changing the spinner speed with the Mark V console requires an optional PWM spinner valve Total Applied Displays total amount of material applied Reset to zero using the Men...

Страница 16: ...nu selection area displays the choices of Machine settings Cal radar Console Diagnostic and GPS The right and left Menu Selection Arrow keys indicate addition selections Each setup area is entered by...

Страница 17: ...r rate Manual speed Maximum conveyor rpm and Spinner pulses rev values can be set one digit at a time Press the Left or Right Arrow key to move a single cursor to the digit to change Press the Up or D...

Страница 18: ...pening metric units are cubic centimeters per revolution per centimeter of gate opening Refer to the tables below for the initial setting This setting becomes the default value for the CFR in each job...

Страница 19: ...lied will be incorrect New Leader recommends using the manual setting for emergency use only In Manual mode the application accuracy depends on the ability of the operator to drive at the programmed m...

Страница 20: ...ctual conveyor rpm will not exceed this setting If the warning to slow down is ignored the rate applied will be incorrect Set to 50 for an L3020G4 Set to 40 for an L2020G4 Spinner pulses rev Set to th...

Страница 21: ...d the display line By pressing the Up or Down Arrow keys set the Actual Distance to equal the distance you marked off c Position the vehicle at the beginning of the marked off distance d Press START T...

Страница 22: ...at a time by using the Left or Right Arrow key to select Serial number Voltage cal and Display brightness values can be set one digit at a time Press the Left or Right Arrow Key to move a single curs...

Страница 23: ...hour Press the Right Arrow key to move to the minutes Use the Up or Down Arrow key to change the minutes Press the Right Arrow key again and change the seconds Press the ACCEPT key Serial number This...

Страница 24: ...roduct Every time a different job is activated for use the Mark V automatically is set to properly apply that product using the stored values Settings for Units acre Application rate Spread width Feed...

Страница 25: ...N OFF EDIT JOB CREATE JOB EXIT Figure 10 Press the CREATE JOB key The screen in Figure 11 appears The settings shown are default settings JOB SETTINGS Units acre Tons Application rate 0 0 tns ac Sprea...

Страница 26: ...g pages Job Setting Details Units acre Set to TONS when applying lime or other high rate product by the ton metric units are tonnes Set to POUNDS when applying fertilizer or like product by pound metr...

Страница 27: ...uld consider that for any active job the name of the product appears in the lower left corner of the main screen To edit the Product a From the Job Settings screen press EDIT key The screen in Figure...

Страница 28: ...an testing every new product to determine the settings necessary for a good spread pattern Consult your spreader manuals for instructions on pan testing Calibrated CFR This value defaults to the theor...

Страница 29: ...a new job edit a job or select a job to delete ACTIVE JOB PRODUCT RATE WIDTH SPINNER ACTIVE UREA 150 65 575 ACTIVE ON OFF EDIT JOB CREATE JOB EXIT Figure 13 To activate a job a Press the Up or Down Ar...

Страница 30: ...d To edit a job a Press the Up or Down Arrow key to highlight the job you want to activate b Press EDIT JOB The Job Settings screen Figure 11 will appear c Use the Up or Down Arrow key to highlight a...

Страница 31: ...pt Press Exit Press the Menu Key ACTIVATING JOBS Press the JOB key Press CHANGE JOB key Press Up or Down Arrow key to highlight desired job Press ACTIVE ON OFF key to check the highlighted job If you...

Страница 32: ...t to the Rate display line If the arrows symbol is not displayed press the adjacent Display Selection Key twice to activate and remove the selection box Press the Up or Down Keys to change to the desi...

Страница 33: ...it will need to be fine tune adjusted to the target speed The closest you should expect to fine tune adjust the speed is within 10 rpm from the target speed To adjust the speed do the following Make...

Страница 34: ...peed sensor or the sensor is faulty the Spinner speed too low alarm will be continuous Setting the Spinner pulses rev to zero found under SETUP key and MACHINE SETTINGS key will disable the alarm CLEA...

Страница 35: ...VE Warning to shut off conveyor when vehicle is stopped DRIVE RPM BELOW MINIMUM Conveyor RPM is below 2 RPM MAXIMUM CONVEYOR RPM SLOW DOWN The conveyor speed is at the set maximum and the application...

Страница 36: ...mmed to automatically recognize the Rawson or New Leader RS 232 protocol according to the following connection settings This is the same protocol used for the Mark III and Mark IV New Leader processor...

Страница 37: ...clearance to bolt head of fins Clearance must be 1 8 or less 5 Check spinner pulses rev setting equals number of fins on disk 6 Faulty sensor Contact dealer Spinner speed will not adjust from main scr...

Страница 38: ...valve Alarm flashes on main screen SPEED ZERO SHUT OFF DRIVE Conveyor switch is on but ground speed is zero 1 Shut off conveyor switch 2 Check radar and radar connections Alarm flashes on main screen...

Страница 39: ...the conveyor switch on to unload a portion of the product If performing a static test turn off the spinners prior to unloading 8 Find the actual weight of product unloaded by weighing the truck and su...

Страница 40: ...mark conveyor shaft and run spreader in manual mode with current settings in processor Count the revolutions the shaft makes in one minute at normal operating RPM This is the actual CRPM EXAMPLE Y 50...

Страница 41: ...r CRPM Conveyor Shaft Revolutions per Minute MW Material Weight Pounds per Cubic Foot CFR Conveyor Rate G 3 000 x 45 x 10 495 x 25 x 90 x 192 G 1 350 000 213 840 G 6 3 is within the RECOMMENDED OPERAT...

Страница 42: ...Ounce 29 57 Milliliters 1 Pound 0 454 Kilogram 1 Cubic Foot ft3 0 028 Cubic Meters M3 1 Pound per Gallon 119 68 Grams per Liter 1 US Gallon per Acre 9 35 Liters per Hectare METRIC TO US 1 Hectare 2 47...

Страница 43: ...hased When broken goods are received a full description of the damage should be made by the carrier agent on the freight bill If this description is insisted upon full damage can always be collected f...

Страница 44: ...OX CABLES ITEM PART NO DESCRIPTION QTY 89001 Mark V Kit Includes 1 1 89002 Console Mark V 1 2 89003 Bracket U 1 3 89004 Hardware Kit Console 1 4 89005 Module Interface 1 5 89006 Cable Power 22 1 6 890...

Страница 45: ...Radar Velocity Sensor Kit 1 1 79860 L Pipe Mounting Bracket Kit 1 Bracket Mounting L Pipe 1 Cap Screw 3 8 16 x 1 1 2 2 Washer Lock 3 8 2 Nut Hex 3 8 16 2 2 79859 Mounting Bracket Kit 1 Bracket Mounti...

Отзывы: