11. Release the safety latch on the inner rails on each side of the chassis as shown in the following image.
Figure 84: Inner Rail Safety Latch Release
12. Push the chassis back into the rack.
13. Locate the M5 x 12mm Philips Pan Head screws on the top cover of the enclosure that keep it in place
when the drawer is extended and unscrew them using a #2 Philips head screwdriver. This will allow the
top cover to move freely with the enclosure when the enclosure is removed.
14. Remove the chassis from the rack.
a) Be prepared to support the enclosure once it is free of the rails by having a second person or a lift to
support the enclosure
b) Grasp both handles at the front of the enclosure and pull with even pressure until the enclosure will
not extend further.
Warning:
The handles on the front of the chassis are not intended to be used to support
the weight of the Ultrastar Data60. Lifting the unit by the chassis handles or trying to support
the unit on the handles can cause them to fail. This can cause serious damage to the unit or
87
4
Part Replacement
User Guide
4.8
Rails Replacement