![HGST Ultrastar Data60 H4060-J Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/hgst/ultrastar-data60-h4060-j/ultrastar-data60-h4060-j_user-manual_2128544157.webp)
The IOMs will reset in a staggered manner. This process can take up to 5 minutes to activate.
7. Ensure multi-pathing can see all of the expected drives.
a) Execute the following command to verify that there are two paths to each drive:
multipath -ll | grep -i “active ready running” -c
8. Ensure Windows MPIO can see all paths to the drives after activating IOM A.
a) Execute the following command:
C:\mpclaim.exe –v C:\Users\Administrator\Desktop\mpclaim_output.txt
b) Verify there are two paths to each drive by issuing the following command:
C:\more C: \Users\Administrator\Desktop\mpclaim_output.txt
Note: It could take the OS several minutes to rebuild all the paths to the drives depending on
the workload on the drives and how busy the host is. Multipathing may have to be verified several
times to ensure that all paths are in an optimal state following the reset of IOM A.
c) Verify that the output from the mpclaim_output.txt output appears similar to the following example.
0000000077010524 Active/Optimized 001|005|036|000 0 Adapter: Avago
Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
134|000|000) Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
0000000077000431 Active/Optimized 000|004|049|000 0 Adapter: Avago
Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
132|000|000) Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
MPIO Disk98: 02 Paths, Least Blocks, ALUA Not Supported SN:
5000CCA2532558CC
Supported Load Balance Policies: FOO RR RRWS LQD WP LB Path ID
State SCSI
Address Weight
---------------------------------------------------------------------------
0000000077010523 Active/Optimized 001|005|035|000 0 Adapter: Avago
Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
134|000|000) Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
0000000077000430 Active/Optimized 000|004|048|000 0 Adapter: Avago
Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
132|000|000) Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
MPIO Disk97: 02 Paths, Least Blocks, ALUA Not Supported SN:
5000CCA253255E9C
Supported Load Balance Policies: FOO RR RRWS LQD WP LB Path ID
State SCSI
Address Weight
---------------------------------------------------------------------------
...
5.1.7
Non-Automatic Firmware Activation in Windows
1. Ensure Windows MPIO can see all paths to the drives.
157
5
System Management
User Guide
5.1
Firmware Upgrade