![HGST Ultrastar Data60 H4060-J Скачать руководство пользователя страница 212](http://html1.mh-extra.com/html/hgst/ultrastar-data60-h4060-j/ultrastar-data60-h4060-j_user-manual_2128544212.webp)
Appendix
A
A Site and System Operation Requirements
A.1
Power Requirements
The following table describes the A/C input power specification for the Ultrastar Data60.
Table 60: AC Power Specifications
Power
Alternating Current (AC) Power Supply (2 per enclosure)
Supply Rating: 80 PLUS Platinum rated
Max Power Consumption:~1250W
Wattage (per power supply)
Note: Max and Typical Power Consumption
values represent the output power to the
Typical Power Consumption:~1000W
system. Input power will vary depending on
the PSU efficiency and load sharing between
PSUs
200 - 240 VAC, auto-ranging, 50/60 Hz
Voltage (per power supply)
Maximum inrush current (per power supply)
Caution: The Ultrastar Data60 can only be plugged into highline. If the unit is plugged into lowline, the
PSU will report a "Critical" state when status pages are queried using SES. In this case, the enclosure
will power up, but the drives will not. The enclosure will remain in low-power mode.
A.2
Supported Operating Systems
A.3
List of Supported Server Components
Table 61: List of Supported CPUs
Wattage
L4 Cache
Cores
Clock Frequency
Product
85W
13.75MB
10 Cores
2.20GHz
Intel Xeon Silver
4114
105W
16.50
12 Cores
2.30GHz
Intel Xeon Gold 5118
212
A
Site and System Operation Requirements
User Guide
A.1