44
50 mm
1200 mm
980 mm
980 mm
980 mm
1200 mm
50 mm
60 mm
718 mm
718 mm
60 mm
Fixing angle
55 mm
2.17”
150 mm
5.90”
60 mm
2.36”
- ProfilGate® i55/sti55/st55/b55/k55
- ProfilGate® b65/st65
Ramp entrance and exit
55 mm
2.17”
250 mm
9.84”
- ProfilGate® i55 go/sti55 go/st55 go/
b55 go
Ramp entrance and exit
65 mm
2.56”
300 mm
11.81”
- ProfilGate® b65 go/st65 go
Entrance/exit ramps for above ground installations
55 mm
2.17”
1200 mm
47.23”
- ProfilGate® i55/sti55/st55/b55/k55
Entrance/exit ramps for above ground installations
65 mm
2.56”
1500 mm
59.06”
- ProfilGate® b65/st65
Calculation of installation dimensions using the
example of a ProfilGate® b55 2x3 field with
ramps. You will find the corresponding
values in the “Technical data” table
for your individual configuration.
(see page 34 /35).
Calculation of field length
Ramp front (length 1200 mm)
1200 mm
+ Number x length ProfilGate® b55 (3 x 980 mm)
2940 mm
+ Ramp rear (length 1200 mm)
1200 mm
= Field length
5340 mm
Calculation of field width
Fixing angle left (width 60 mm)
60 mm
+ Number x width ProfilGate® b55 (2 x 718 mm)
1436 mm
+ Fixing angle right (width 60 mm)
60 mm
= Field width
1556 mm
Installation above ground with entrance and exit ramps
www.nsltechnology.com
Содержание ProfilGate b55
Страница 31: ...55 EN www nsltechnology com...