40
1-5 mm
up to 0.2”
60-200 mm
2.4 to 8”
65 mm
2.56”
4-8 mm
0.16 to 0.32”
1-5 mm
up to 0.2”
60-200 mm
2.4 to 8”
55 mm
2.17”
4-8 mm
0.16 to 0.32”
min.
60 mm
718 mm
718 mm
min.
60 mm
min.
60 mm
980 mm
980 mm
980 mm
min.
60 mm
Calculation of pit width
Gap left (recommendation 60-200 mm)
min. 60 mm
+ Number x width ProfilGate® b65 (2 x 718 mm)
1436 mm
+ Joint right (recommendation 60-200 mm)
min. 60 mm
= Pit width
min. 1556 mm
Calculation of pit length
Joint front (recommendation 60-200 mm)
min. 60 mm
+ Number x length ProfilGate® b65 (3 x 980 mm)
2940 mm
+ Joint rear (recommendation 60-200 mm)
min. 60 mm
= Pit length
min. 3060 mm
Calculation of pit depth
Height of tray ProfilGate® b65 (65 mm)
65 mm
+ Space for filler/adhesive
(recommendation 3-5 mm)
min. 3 mm
= Pit depth
min. 68 mm
Tray depth 65 mm
- ProfilGate® b65
- ProfilGate® b65 dryzone
- ProfilGate® st65
Tray depth 55 mm
- ProfilGate® b55
- ProfilGate® i55
Ground level installation
- ProfilGate® st55
- ProfilGate® sti55
Tray
Grate
Filler/adhesive 1-5 mm under the tray
Levelling compound
Maintenance joint 4-8 mm polyurethane
Joint filling 60 - 200 mm around the entire
Cleaning field (outer edge)
Calculation of pit dimensions using the example
of a ProfilGate® b65 2x3 fields. You will find the
corresponding values in the “Technical data”
table (see page 34) for your individual
configuration.
www.nsltechnology.com
Содержание ProfilGate b55