Fault reports and their correction
72
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
Nr. Fault text
Reason
Suggestions for rectifying
032
ANTIFREEZE HEATING
CIRCUIT
ANTIFREEZE HEATING
CIRCUIT 7°C
-
033
ANTIFREEZE SOLAR
Collector temperature under set up
antifreeze temperature
-
034
ANTIFREEZE HYDR.
COMPENSATOR
Hydraulic compensator temperature
under 7°C
-
035
ANTIBLOCKING BACK
FLOW
Blocking protection activated for
return flow pump. Return flow pump
triggered for 10 s approx.
-
036
ANTIFR. ADD. BOILER
Additional boiler temperature under
7°C
-
037
HOT WATER TANK
LOADING
Hot water tank didn´t reach set
temperature during loading time; hot
water tank loading gets blocked till
fault correction.
Adapt loading time
Activate hot water tank priority
Hot water tank settings (min. / set)
038
MAINTENANCE
This fault text occurs after 1000
operating hours
Conduct maintenance according to
maintenance schedule (see chapter:
Settings
Code
If code is already set
Settings
039
SERVICE
This fault text occurs after 3000
operating hours
Carry out boiler system
maintenance by authorised
personnel
040
OVERHEAT ADD.BOILER
ZSK
This fault text occurs if additional
boiler temperature exceeds 92°C
-
041
HEATING OFF
System is on
„Heating Off“
-
042
BLOCKING
PROTECTION
Blocking protection is conducted
-
043
TIMEOUT ADD. BOILER
Additional boiler minimum flue gas
temperature wasn´t reached within
1 hour (operation mode:
automatic/burner)
Check additional boiler
044
LEGIONELLA PROT.
Thermal disinfection in storage tank
activated-Storage tank will be
heated to 75°C
-
045
CHIMNEY SWEEPER
MODE
Chimney sweep function activated
(see chapter 11.4)
046
MOD.ERR EXT.
Error in communication via CAN 2
with an external module
Check module CAN connection
Check module
✆
-
contracting party
047
MOD.ERR INT.
Error in communication via CAN 1
with an internal module
Check module CAN connection
Check module
✆
- contracting party
048
MOD.ERR BOILER
Error in communication with the
boiler module
Check module CAN connection
Check module
✆
- contracting party
049
DATAERROR MINNE
EXTERNT
Error in communication with the
boiler module
✆
- contracting party
050
DATAERROR MINNE
INTERNT
Error in communication with the
boiler module
✆
- contracting party
051
DATAERROR MEMORY
BOILER
Error in the adjustment data in the
boiler module
✆
- contracting party
Содержание pelletfire
Страница 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Страница 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Страница 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Страница 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Страница 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Страница 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Страница 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Страница 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Страница 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Страница 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Страница 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...