11
Description of the menu navigation and adjustment values
32
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
Term
Description
Unit
Overview II
Operation mode
Display the operation mode (Automatic mode, Log wood mode or
ignition Log wood)
-
Log wood mode
Display the operation mode
-
Pellets mode
Display the operation mode
-
Buffer load status
In the "Overview II" the buffer load status depending on the charge
state is shown in different colors:
Buffer displayed in red means that the buffer is full.
Buffer displayed in red-blue means that the buffer is half full.
Buffer displayed in blue means that the buffer is empty.
-
Status I
Boiler temperature
Display of the boiler temperature (55-90)
°C
Back flow temperature
Display of the back flow temperature (>60)
°C
Flue gas temperature
Display of the flue gas temperature (= flue gas temperature)
°C
Boiler power
Display of the current boiler output
%
Back flow mixer
Indication of the actual state (OPEN/CLOSE) of the back flow mixer
-
Back flow pump
Indication of the actual state (ON/OFF) of the back flow pump
-
Status II
Stoker temperature
Display of the stoker screw temperature (= feeding screw temperature)
°C
Burning chamber
temperature
Display of the burning chamber temperature (= temperature in the
combustion chamber)
°C
ID Fan
Display of the actual power of the ID-fan.
%
Rotation speed
Display of the actual rotation speed of the ID-fan.
%
Burner air flap
Display the value of the burner air flap.
%
Status III
ID fan correction
Display of the actual induced-draught fan correction of the lambda
control
%
Material correction
Display of the actual material correction of the lambda control
%
Insertion - tact
Display of the stoker screw (= feeding screw) interval, when fuel is fed in
burning chamber
-Interval is adjusted by the customer service!
0,1 s
Insertion - pause
Display of the stoker screw (= feeding screw) interval, when no fuel is
fed in burning chamber
-Interval is adjusted by the customer service
0,1 s
O2 [%]
Display of the actual fuel gas O2-content (oxygen content).
%
CO2 [%]
Display of the actual fuel gas CO2-content (carbon dioxide content)
%
Status IV
Log wood - buffer top
Display of the actual Log wood - buffer top (30-65)
°C
MODUL
Boiler
Buffer
Hot water tank
Heating circuit
Time mode
Solar
Hydr.compensat
Net pump
Zone valve
Ext. requirement
addit. boiler
Содержание pelletfire
Страница 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Страница 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Страница 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Страница 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Страница 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Страница 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Страница 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Страница 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Страница 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Страница 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Страница 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...