11
Description of the menu navigation and adjustment values
42
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
Term
Description
Unit
Circulation pump
Activates the circulation pump (ON/OFF)
During the hot water tank loading time the circulation pump is switched
on 2 minutes for every 10 minutes
If circulation pump is activated, „circulation pump“ is available at the
agg-test and the parameter seting (0-85, limited to hot water tank target
temperature)
-
°C
Loading valve
Activates the loading valve (ON/OFF)
If loading valve is activated, „loading valve“ is available at the agg-test
(
only if loading valve is installed)
-
Time program
Time 1
Three different time options are available:
time 1:
08:00
– 10:00
time 2:
15:00
– 21:00
time 3:
00:00
– 00:00
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday
-
Monday preset gets assigned to remaining weekdays
-
Circulation time
Time 1
Three different time options are available:
time 1: 08:00
– 10:00
time 2: 15:00
– 21:00
08:00
– 11:00
Setting up individual circulation pump in operation of every weekday.
Monday preset gets assigned to remaining weekdays
Agg-Test
Hot water tank pump*
Indicates the state of the hot water tank pump:
If the indicator lamp lights up, the hot water tank pump is running
Only visible, if “loading valve” is not activated
-
Loading valve*
Indicates the state of the loading valve:
If the indicator lamp lights up, the loading valve is open
Only visible, if “loading valve” is activated
-
Load-through valve*
Indicates the state of the load-through valve:
If the indicator lamp lights up, the load-through valve is open and the
hot water tank is loaded faster (= fast start)
Only visible, if “loading valve” is activated
-
Circulation pump*
Indicates the state of the circulation pump:
If the indicator lamp lights up, the circulation pump is running
Only visible, if “circulation pump” is activated
-
MODUL
Boiler
Buffer
Hot water tank
Heating circuit
Time mode
Solar
Hydr.compensat
Net pump
Zone valve
Ext. requirement
addit. boiler
Содержание pelletfire
Страница 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Страница 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Страница 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Страница 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Страница 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Страница 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Страница 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Страница 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Страница 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Страница 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Страница 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...