Fault reports and their correction
12
Betriebsanleitung_pelletfire_Touch_Englisch_V1.2
71
Nr. Fault text
Reason
Suggestions for rectifying
019
SENSOR COLLECTOR
BACK FLOW
Failure solar collector back flow
temperature sensor
Check sensor, replace as
necessary
Check plug, replace as necessary
Check wiring incl. Connections,
replace as necessary
✆
- contracting party
020
SENSOR SOLAR TANK 1
Failure solar tank 1 temperature
sensor (hot water tank/buffer)
Check sensor, replace as
necessary
Check plug, replace as necessary
Check wiring incl. Connections,
replace as necessary
✆
- contracting party
021
SENSOR SOLAR TANK 2
Failure solar tank 2 temperature
sensor (hot water tank/buffer)
Check sensor, replace as
necessary
Check plug, replace as necessary
Check wiring incl. Connections,
replace as necessary
✆
- contracting party
022
SENSOR SOLAR
RESERVE
Failure solar tank temperature
sensor reserve (hot water
tank/buffer)
Check sensor, replace as
necessary
Check plug, replace as necessary
Check wiring incl. Connections,
replace as necessary
✆
- contracting party
023
ADDITIONAL BOILER
SENSOR
Failure Additional boiler sensor;
cable break; short-circuit; failure
connection
Check sensor, replace as
necessary
Check plug, replace as necessary
Check wiring incl. Connections,
replace as necessary
✆
- contracting party
024
HYDR. COMP. SENSOR
Failure hydraulic compensator
temperature sensor; cable break;
short-circuit; failure connection
Check sensor, replace as
necessary
Check plug, replace as necessary
Check wiring incl. Connections,
replace as necessary
✆
-
contracting party
025
OVERHEAT BOILER
MAY
Heat generator temperature is
above 98°C
Check settings
Check back flow mixer
Check back flow pump
026
OVERHEAT
Heat generator temperature is
above 92°C
Check settings
Check back flow mixer
Check back flow pump
027
SOLAR OVERHEATING
Fault is shown, if collector
temperature exceeds 140 °C
Check solar pump
Check solar tank level
028
SOLAR MAX. LOADING
Collector temperature exceeds 120
°C
-
029
ANTIFREEZE BOILER
Boiler temperature respectively
operation room temp. under 7°C
-
030
ANTIFREEZE BUFFER
Buffer bottom sensor temperature
under 7 °C
-
031
ANTIFREEZE HOT
WATER TANK
Hot water tank under 7°C
-
Содержание pelletfire
Страница 1: ...Operating instructions Log Wood Pellet heatingsystem pelletfire 20 40 ...
Страница 86: ...16 Annex 86 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Hydraulic recommendation 2 ...
Страница 87: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 87 16 2 Solar module Program 1 ...
Страница 88: ...16 Annex 88 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 2 ...
Страница 89: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 89 Program 3 ...
Страница 90: ...16 Annex 90 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 4 ...
Страница 91: ...Annex 16 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 91 Program 5 ...
Страница 92: ...16 Annex 92 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 Program 6 ...
Страница 93: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 93 17 NOTES ...
Страница 94: ...17 Notes 94 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 ...
Страница 95: ...Notes 17 Betriebsanleitung_pelletfire_Touch_Englisch_V1 2 95 ...