5.1 Water supply
The unit is equipped with two water connections:
●
a soft water connection for producing steam
●
a hard water connection for cooling waste water, for operating the
hand shower and for the automatic cleaning system “WaveClean”
For units that are equipped with the “WaveClean” automatic cleaning
system, use of “WaveClean” is not possible without a hard water
connection.
NOTICE
Both water supplies must always be connected.
Hard and soft water connections can be made via a hose with a T-piece
(accessory) in the event that only soft water is available on site (see
Chapter “Fitting the T-piece (accessory)”, Page 30
NOTICE
When using the stacking kit (accessory), the upper and lower units must
be connected independently so that the other unit can still be used in
the event that one unit fails.
1.
Observe information about the hard water supply (see
“Information about the hard water supply”, Page 30
2.
Observe information about the soft water supply (see
“Information about the soft water supply”, Page 29
).
3.
Ensure that customer-supplied water hoses fulfil the requirements
for the hard and soft water supplies (see
Chapter “Specifications, hard water”, Page 13
4.
Make sure that the provisions for the supply of drinking water are
complied with (see
5.
Ensure that the water stop-cock is fitted with a backflow preventer.
6.
Use ½" hoses with an R ¾" thread permitted for connecting drinking
water for the connection.
NOTICE
Use DVGW-tested hoses, or hoses conforming to the local regulations,
according to IEC 61770.
Global Foodservice Solutions
Planning and installation instructions
28
Space
$aver
™
Water