A
B
If the unit is to be connected to the mains as a single-phase appliance,
the contactor terminal connections and those of the electronic relay
must be changed. The contactor's terminal blocks are located under
the cover on the left at the back (A). The electronic relay is under the
cover on the right at the back (B).
1.
Prepare the connection cable (cable type H07RN-F compliant with
EN-Norm).
2.
Remove covers.
3.
At the contactor, connect the blue wire from terminal Y to terminal
N.
4.
At the electronic relay, connect the black wire from terminal V1 /
2/T1 to terminal V2 / 2/T2.
5.
Replace covers.
6.
Remove the back panel.
7.
Pass the connection cable through the strain relief screws into the
unit.
8.
Tighten the strain-relief screws securely so that the power cable
cannot be pulled out.
25
Planning and installation instructions
Global Foodservice Solutions
Electricity
Space
$aver
™