14

STEP 5D – Volume of water used, 63-day usage history:

 This display shows day 0 (for today) 

and 1 (for yesterday) will show day 2 (which would be the day before yesterday) and flashes 

the volume of water treated on that day.  Continue to press the  

 

button to show the volume of 

water treated for the last 63 days.  If a regeneration occurred on the day the "letter R" will also be 

displayed.  This display will show dashes if a water meter is not installed.  Press the NEXT button 

at any time to go to Step 6 D.  Press REGEN to return to the previous step.

STEP 6D

 – 

Flow rate,

 maximum of each of last seven days: The maximum flow rate in gallons 

per minute that occurred in each of the last seven days will be displayed.  Press 

 

arrow to 

display maximum flow rate today = 0, yesterday = 1.  This display will equal zero if a water meter 

is not installed.  Press the NEXT button to go to Step 7D.  Press REGEN to return to the previous 

step.

STEP 7D

 – 

MAV Drive History –

 Not displayed if MAV set to off.

• First - Average of 1st three drive times of MAV in that direction

• Last - Last drive time measured for that MAV in that direction

• Ave - Average drive time measured for MAV in that direction

• TTT - Drive time (1424 = 14.24 seconds)

• CCC - Total number of cycles for that MAV

• VVV - Relative drive voltage

MAV drives piston "in" is designated by (-) sign.

MAV drives piston "out" is designated by (+) sign.

Any time MAV  is rebuilt or replaced, reset diagnostics to reflect new drive characteristics.

STEP 6D

12.7

RETURN TO NORMAL MODE

STEP 5D

USAGE HISTORY  

DAY

  

108

GAL

  

GAL

  

MAX FLOW

DAY

  

6

1

STEP 1VH – 

Press 

 

and 

 

simultaneously for three seconds and release, then press 

 

and 

 

simultaneously and release.  If screen in step 2VH does not appear in 5 seconds the lock on the 

valve is activated.

STEP 2VH 

 Days, total since start-up:

 This display shows the total days since startup.  Press 

the NEXT button to go to Step 3VH.  Press REGEN to return to previous step.

STEP 3VH 

– 

Regenerations, total number since start-up:

 This display shows the total number 

of regenerations that have occurred since startup.  Press the NEXT button to go to Step 4VH.  

Press REGEN to return to previous step.

STEP 4 VH 

– 

Volume, total used since start-up:

  This display shows the total gallons treated 

since startup.  This display will equal zero if a water meter is not installed.  Press NEXT button to 

exit Valve History.  Press REGEN to return to 

previous step.

STEP 5 VH 

– 

Error Log history:

  up to 10 errors.  Press 

 

and 

 

buttons to view each recorded 

error. If no errors have occurred " – – – –" is displayed.  With STALL ERRORS 102, 107, 117, right 

upper corner of display indicates piston position at time of stall.  Press NEXT to exit valve history.

STEP 1VH

VALVE HISTORY

STEP 2VH

970

TOTAL  DAYS  

STEP 3VH

235

STEP 4VH

175

GAL

x1K

(Can not be reset)

TOTAL REGENS  

TOTAL GALLONS

RETURN TO ROTATING DISPLAY

1- - -

ERROR LOG

STEP 5VH

STEP 7D

CCC

TTT  

ALT + FIRST

CYC

VVV 

XXXX

Содержание H-125 HE Series

Страница 1: ...vian Valley Road Waunakee Wisconsin 53597 www hellenbrand com info hellenbrand com p n 109122 Rev G Updated 8 30 18 2008 2018 System for Automatic Discharge Management U S Patent No 9 862 619 Method o...

Страница 2: ...g Conditions 4 Pre Installation Check List 5 Bypass Valve Operation 5 Water Softener Disinfection 5 Installation Instructions 6 Programming 7 16 Set Time of Day Softener Setup Service Reminder Diagnos...

Страница 3: ..._______________________________________________________ The average family uses 50 gallons per person daily for all water uses in the home about 30 gallons per person daily if soft water is not suppli...

Страница 4: ...uple of weeks initially to determine how much salt you use this will depend on how much water you use As a rule of thumb with 20 gpg hard water about a 1 2 lb of salt per person per day is used In oth...

Страница 5: ...a bypass valve Softening It is recommended that the conditioner be installed to soften both the hot and cold water supply A separate hard water faucet may be plumbed for drinking purposes if you desi...

Страница 6: ...itting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control fitting Failure to do this could cause interior damag...

Страница 7: ...ys BACKWASH Keep in backwash until water once again runs clear at the drain 10 Press REGEN button again until RINSE is displayed Allow rinse cycle to run its full course While the rinse cycle is finis...

Страница 8: ...s sets the number of days between regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a number allowable range from 1 to 28 a regeneration init...

Страница 9: ...s of each cycle STEP 1S STEP 2S SOFTENING STEP 3S FILL 20 0 STEP 1S Press NEXT and simultaneously for 3 seconds If screen in Step 2S does not appear in 5 seconds the lock on the valve is activated STE...

Страница 10: ...s capacity is affected by the fill time The grains capacity for the selected lbs salting should be confirmed by testing The capacity and hardness levels entered are used to automatically calculate res...

Страница 11: ...ps registering flow which ever comes first Press NEXT to go to 19S for programming Service Alarm Relay activates on service alarm setting gallons time or both see step 21S Relay Triggered for Lockout...

Страница 12: ...down arrows to select start time into regeneration to energize relay regeneration is defined by start of backwash or draw whatever comes first Range 20 500 minutes or select REGEN Select REGEN if rel...

Страница 13: ...URN TO NORMAL MODE DIAGNOSTICS STEP 2D 2 DAYS SINCE REGEN STEP 3D 342 GAL STEP 1D DAY SINCE LAST REGEN STEP 1D Press or simultaneously for three seconds If screen in step 2D does not appear in 5 secon...

Страница 14: ...on out is designated by sign Any time MAV is rebuilt or replaced reset diagnostics to reflect new drive characteristics STEP 6D 12 7 RETURN TO NORMAL MODE STEP 5D USAGE HISTORY DAY 108GAL GAL MAX FLOW...

Страница 15: ...1 25 SET STEP 3CS OFF ALTERNATOR SYSTEM SET VALVE TYPE ALT A ALTERNATOR SYSTEM SET STEP 4CS STEP 5CS REFRESH RINSE SET TYPE MIN STEP 4CS Twin Alternating System Allows automatic alternation between t...

Страница 16: ...ntrol Valve for Separate Source Operation Select Separate Source Enabled for control operation For separate source opera tion the three wire connector is not used Selection requires that a connection...

Страница 17: ...fill flow control retainer assembly from the elbow Reinstall the elbow assembly and secure with the locking clip Disconnect the brine tube at the top of the salt keeper and force air into the brine tu...

Страница 18: ...ans former if inadequate voltage 4 Low battery after power outage D1 If power outage occurred and battery on board has low voltage the microprocessor may not recover cleanly and display properly Disco...

Страница 19: ...specification C Excessive water in brine tank C See problem 9 D Leaking faucets toilets etc D Repair or replace those items E Brine line flow control out of place E Replace Brine line flow control 7 L...

Страница 20: ...eter D Unplug meter from PC board if LED display lights appropriately replace meter E Defective PC board E Replace PC board 15 Control does not display correct A Power outage 2 years A Reset time of d...

Страница 21: ...SBV 8 Grid 1 104421 c 18X40 w 474 SBV 11 Grid 1 104423 d 24x50 w 474 SBV 6 Grid 1 104428 e 24x50 w 474 SBV 9 Grid 1 104423 f 18x40 w 474 SBV No Grid 1 104416 g 24x50 w 474 SBV No Grid 1 104426 h 30x50...

Страница 22: ...H125 PC Board 1 5 101746 Drive Gear 12x36 3 6 101459 Drive Gear Cover 1 Not Shown 103723 Optional Relay Kit PCM 1 Not Shown 103729 Optional Relay Kit 120V Pigtail Not Shown 101880 Auxiliary Switch Ki...

Страница 23: ...Plug 1 101825 Injector Assembly A Black 101826 Injector Assembly B Brown 101827 Injector Assembly C Violet 101828 Injector Assembly D Red 101829 Injector Assembly E White 5 101830 Injector Assembly F...

Страница 24: ...ystems 1 102322 H125 H150 Refill Port Plug Assy 1 2 101154 H125 H150 BLFC Adapter 1 3 101414 Locking Clip 1 4 102417 H125 H150 Refill Retainer Assy 1 4 8 103590 1 2 Refill Elbow Assy 1 5 102153 O Ring...

Страница 25: ...ine oils other hydrocarbon lubricants or spray silicone anywhere Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connec tion Teflon tape is not necess...

Страница 26: ...ss Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 214 2 Bypass Valve Not Shown Bypass Vertical Adapter Assembly ORDER NO DESCRIPTION QTY 10...

Страница 27: ...with a hammer Do not use vaseline oils other hydrocarbon lubricants or spray silicone anywhere Teflon tape must be used on threads of the 1 NPT connection and on the threads for the drain line connec...

Страница 28: ...28 FLOW DIAGRAMS SERVICE AND BACKWASH FLOW DIAGRAMS RINSE AND FILL...

Страница 29: ...or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Wrench part number is 102892 Loosens Drain Nut in Polytube Applications L...

Страница 30: ...n gallons capacity reaches 0 Time of regeneration will not be allowed to be set because of regeneration will always occur when gallons capacity reaches 0 DELAY IMMEDIATE oFF Reserve capacity not autom...

Страница 31: ...board The drive gear cover is held in place on the drive bracket by three clips The largest of the three clips is always orientated to the bottom of the drive bracket With the PC board facing up push...

Страница 32: ...force the spacer stack assembly in The control valve body bore interior can be lubricated with silicone to allow for easy insertion of the entire stack Do not use silicone or any other type of lubric...

Страница 33: ...urbine to remove it from the shaft Do not use a wire brush to clean the turbine Wipe with a clean cloth or chemically clean in dilute sodium bisulfite or vinegar The turbine can be immersed in the che...

Страница 34: ...34 SERVICE RATES PRESSURE DROP CHARTS...

Страница 35: ...e Tank NO NO NO NO NO NO NO 3 8 3 8 3 8 3 8 3 8 3 8 3 8 2 2 2 2 4 2 4 2 5 3 7 5 7 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 D RED E WHITE G YELLOW H GREEN I ORANGE J LT BLUE K LT GREEN 0 22 0 27 0 46 0 46 0 56 0...

Страница 36: ...RANTY DOES NOT COVER defects caused by sand sediment or bacteria fouling accident fire flood Act of God misuse misap plication neglect alteration installation or operation contrary to Hellenbrand s pr...

Отзывы: