11
STEP 11 S – Set Regeneration Time Options
using the
or
button. If value is set to:
• “DELAY” means regeneration will occur at the preset time; (page 8, step 4)
• “IMMEDIATE” means regeneration will occur immediately when the gallons capacity reaches 0 (zero); or
• “DELAY + IMMEDIATE” means regeneration will occur at one of the following:
- the preset time when the gallons capacity falls below the reserve or the specified number of days be
-
tween regenerations is reached, whichever comes first; or
- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).
-Delay + Immediate is NOT available if control is programmed as a twin alternating configuration. Select
-
ing "DELAY" will result in an immediate alternation upon capacity depletion but regeneration is delayed to
preset time.
See page 33 for more options.
Factory Setting is DELAY + IMMEDIATE.
Press NEXT to go to Step 12S.
Press REGEN to return to previous step.
STEP 12 S –
Set Relay to activate by Time, Gallons, Regen Gallons, Lockout, Off or
Service Alarm
by using
or
buttons. A relay can be used to operate a chemical feed pump or sole
-
noid, etc. The choices are:
• Relay Triggered on Time - Relay activates after set number of minutes after start of regeneration. Start of
regeneration is defined by first backwash cycle, dn brine or up brine, whichever is first. Relay deacti
-
vates after set time. Press NEXT for programming.
• Relay Triggered on Gallons - Relay activates every set number of gallons while in service and deacti-
vates after set time. Press NEXT to go to 16S for programming.
• Relay Triggered on Regen Gallons - Relay activates after set number of gallons in service
or
gallons
used during regeneration and de-activates after set time or when meter stops registering flow, which
-
ever comes first. Press NEXT to go to 19S for programming.
• Service Alarm
- Relay activates on service alarm setting: gallons, time or both, see step 21S.
•
Relay Triggered for Lockout
- Relay is activated at set number of minutes into regeneration including
negative numbers to energize relay prior to regeneration starting. Selection of energizing relay for
complete regeneration cycle is available by selecting REGEN for time setting, see step 22S.
•
Off
- If off is selected, Steps 13S – 24S will not be shown.
Factory setting = OFF
. Press NEXT to
go to step 13S or other selection for relay settings, or 25S if OFF selected.
STEP 11S
DELAY + IMMEDIATE
REGEN
SET
RELAY 1 DURATION
STEP 13S
RELAY 1 SET POINT
10
MIN
RELAY 1 DURATION
3:00
MIN
STEP 14S
RELAY 1 SETPOINT
GAL
1
SET
STEP 12S
RELAY 1 "TIME"
TRIGGER
SET
SET
SET
SET
0:01
MIN
RELAY 1 "GALLONS"
TRIGGER
SET
STEP 15S
STEP 17S
STEP 16S
STEP 13 S –
If off was selected in previous step, this screen does not appear.
Time chosen to Activate Relay,
use up and down arrows to set # of minutes
AFTER START OF REGEN to activate relay.
Start of regeneration is defined as
first Backwash or Regenerant Draw mode. Time Range = 1 – 500 minutes. Press
NEXT to go to Step 14S.
STEP 14 S –
Use Up and Down arrows to set duration of relay activation in minutes.
Range is 0:01 (1 second) to 500:00 (500 minutes). Press NEXT to go to Step 25S.
Press REGEN to return to previous step.
STEP 16 S –
Use up and down arrows to set # of gallons per relay activation.
Range = 0.1 – 20,000 gallons. Press NEXT for Relay Duration. Press REGEN to
return to previous step.
STEP 17 S –
Use up and down arrows to set duration of relay activation in minutes.
Range = 0:01 (1 second) - 500:00 (500 minutes). Press NEXT to go to Step 25S.
Press REGEN to return to previous step.
STEP 15 S –
Gallons chosen to activate relay.
If Off or Time was selected in previous steps, this screen
does not appear. Press NEXT for trigger programming.
➔
➔
➔
➔
➔
➔
➔