Rectification of malfunctions
S. 116
17.2
LED on heatapp! gateway
LED
Description
Steady white
Start sequence step 1 - power supply switched on
Boot error - If the LED light up in white after switch on for more than two minutes, disconnect the
heatapp!
gateway
from the power supply and wait for one minute. Reconnect the
heatapp! gateway
to the power
supply.
Steady yellow
Start sequence step 2 - starting of the operating system
Flashes green
Start sequence step 3 - create network and Internet connection
Steady green
Network and Internet connection created
Steady yellow
Network connection made, no
heatapp! base
found.
Check network configuration!
Steady red
No network connection possible.
LAN: No network cable connected?
Wi-Fi: Incorrect access data?
Flashes red
System fault - update via Internet / USB necessary.
Contact your contractor / installation company.
17.3
Fault messages
17.3.1
heatapp! drive
Display
Description
E1 ... E4
Fault message E1 to E4 at the heatapp! drive indicate an actuator defect.
Contact your contractor / installation company and have the heatapp! drive replaced.
E5
Fault message E5 means the
heatapp! drive
cannot connect to the
heatapp! gateway
.
Check the position and function of the repeaters.
Check the position of the
heatapp! gateway
.
Restart the
heatapp! gateway
(disconnect the power supply for 20 seconds).
Perform the function “Repair radio system”.
In most cases the devices reconnect within a few hours and the fault message disappears.
If the fault message persists for more than 5 hours, remove and reinsert the batteries of the
heatapp! drive
.
Then perform the function “Repair radio system” (see section “Function Repair radio system).
If the error cannot be cleared, disconnect the
heatapp! gateway
for at least one minute from the power
supply.