Heat & Glo • SL-750TRS-IPI-D, SL-550TRS-IPI-D, SL350TRS-C • InD • 2065-985 Rev. o • 3/07
41
E. Junction Box Installation
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
Figure 10.3 Junction Box Detail
If the box is being wired from the
OUTSIDE
of
the appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.3).
• Install the supplied Romex
™
connector in the
cover plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and reat-
tach the cover plate to the outer shell.
If the box is being wired from the
INSIDE
of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell
(see Figure 10.3).
• Pull the electrical wires from outside the ap-
pliance through this opening into the valve
compartment.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the
junction box/receptacle and reassemble the
junction box/receptacle to the outer shell.
NOTE:
Do NOT wire
110VAC to wall switch.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.4):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female con-
nector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.
Red
Red
Black
Black
Green
Green
White
White
Red
Black
Green
White
SWITCH BOX
JUNCTION BOX
POWER
SUPPLY WIRES
SWITCH
MINIMUM 14-3 AWG
WITH GROUND
Figure 10.4 Junction Box Wired to Wall Switch