Heat & Glo • SL-750TRS-IPI-D, SL-550TRS-IPI-D, SL350TRS-C • InD • 2065-985 Rev. o • 3/07
39
A. Recommendation for Wire
This appliance uses standing pilot ignition and requires
110-120 VAC be wired to the junction box for use of
optional accessories.
Electrical Information
10
NOTE:
This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with
National Electric Code ANSI/NFPA 70-latest
edition
or the
Canadian Electric Code, CSA C221.1
.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
• If using thermostat use one compatible with a millivolt
gas valve system.
• Follow parameters for locating thermostat (see individ-
ual thermostat instructions) to ensure proper operation
of appliance.
C. Standing Pilot Ignition System Wiring
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Shock hazard.
• Replace damaged wire with type 105
O
C
rated wire.
• Wire must have high temperature insulation.
WARNING
• This standing pilot ignition system wiring does not
require a 110 VAC supply to operate.
• It is recommended that a 110 VAC junction box be in-
stalled for use with a fan or remote control. (See Figure
10.2 for junction box wiring).
Figure 10.1 Standing Pilot Ignition Wiring Diagram
• Use low resistance thermostat wire for wiring from igni-
tion system to the wall switch and thermostat.
• Keep wire lengths short as possible by removing any
excess wire length.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
THERMOSTAT
WIRE ASSEMBLY
PIEZO
WHITE
RED
VALVE
PILOT
THERMOCOUPLE