Heat & Glo • SL-750TRS-IPI-D, SL-550TRS-IPI-D, SL350TRS-C • InD • 2065-985 Rev. o • 3/07
9
A
Top View
INTERIOR WALL
FIREPLACE
OPENING
B
MANTEL LEG OR WALL PROJECTIONS
D. Mantel Projections
Figure 3.3 Clearances to Mantels or other
Combustibles above Appliance
Figure 3.4 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
2”
4"
5”
6”
7”
8”
9”
2"
3"
4"
5"
12"
11"
10"
9"
8"
7"
6"
TOP FRONT EDGE
OF FIREPLACE
3”
11”
12”
10”
31”
CEILING
1”
1”
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
3
4
5
6
7
8
Millimeters
76
102
127
152
178
203
B
Inches
1
2
3
4
5
f
Millimeters
25
51
76
102
127
f