B. Disassembly of Vent Sections
(DVP Pipe ONLY)
Securing the Vent Sections
Vertical Sections
Vertical sections of pipe must be supported every 8 feet
after the 25 foot maximum unsupported rise. The vent sup-
port or plumber’s strap (spaced 120° apart) may be used
to do this (see Figure 8.8).
Horizontal Sections
Horizontal sections of vent must be supported every 5 feet
with a vent support or plumber’s strap.
Figure 8.8 Securing Vertical Pipe Sections
To disassemble any two pieces of pipe, rotate either section
(see Figure 8.10), so that the seams on both pipe sections
are aligned (see Figure 8.11). They can then be carefully
pulled apart.
Figure 8.11 Align and Disassemble Vent Sections
Figure 8.10 Rotate Seams for Disassembly
Figure 8.9 Securing Horizontal Pipe Sections
Fire Risk.
Explosion Risk.
Combustion Fume Risk.
Use vent run supports per installation
instructions.
Connect vent sections per installation
instructions.
• Maintain all clearances to combustibles.
• Do NOT allow vent to sag below
connection point to appliance.
Improper support may allow vent to sag or separate.