Heat & Glo • SL-750TRS-IPI-D, SL-550TRS-IPI-D, SL-350TRS-C • InD • 2065-985 Rev. o • 3/07
60
Maintaining and Servicing Appliance
15
Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali
¿
ed
service technician should perform an appliance checkup at the beginning of each heating season.
WARNING
Annual inspection by quali
¿
ed technician recommended.
Check:
• Condition of doors, surrounds and fronts.
• Condition of glass, glass assembly and glass seal.
• Obstructions of combustion and ventilation air.
• Condition of logs.
• Condition
of
¿
rebox.
• Burner ignition and operation.
• Burner air shutter adjustment
• Gas connections and
¿
ttings.
• Obstructions of termination cap.
Clean:
• Glass
• Air passageways, grilles,
control
compartment
• Burner, burner ports
Risk of:
• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors
Handle glass assembly with care.
NOTE:
Clean glass after initial 3-4 hours
operation.
Longer operation without
cleaning glass may cause a permanent
white
¿
lm on glass.
CAUTION
When cleaning glass door:
• Avoid striking, scratching or slamming glass.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white
¿
lm.
• Do NOT clean glass when hot.
• Turn off appliance after 3-4 hours of operation and
ALLOW TO COOL.
• Remove and clean glass assembly.
• Replace glass assembly and operate appliance for
additional 12 hours.
Refer to maintenance instructions.
Risk of injury or property damage.
Before servicing:
• Turn off gas.
• Turn off electricity to appliance.
• Disable remote control, if one is present.
• Ensure appliance is completely cooled.
After servicing:
• Replace any screen or barrier that was removed.
• Reseal and reinstall any venting removed for servicing.
WARNING
Inspect external vent cap regularly.
• Ensure no debris blocks cap.
• Combustible materials blocking cap
WARNING
may ignite.
• Restricted
air
À
ow affects burner operation.